Neelim للاستشارات الصحية
Neelim

Radiographer Prometric exam questions

Positioning, physics, radiation protection, CT/MRI and patient care.

Tell us which regulator you are sitting and we send the bank prepared for that authority's exam.

For DHA · DOH · MOHAP · SHA · SCFHS · QCHP · NHRADHA RAD5152Pass mark DHA 55% · QCHP 50%From 3 papers · ~160 Qs each
AED 269one-time
About a third of one exam fee
Request this question bank

Tell us your authority and we send the bank for that exam, usually the same day.

Or sit 25 questions free first →

What is riding on this exam

~AED 880
DHA exam fee, per attempt
Paid again on every re-sit. Other regulators' fees are in the table below.
3
UAE attempts - in total
Shared across DHA, DOH, MOHAP and SHA, not three each. Saudi, Qatar, Oman and Kuwait rules are in the FAQ.
50-55%
Pass mark, by regulator
DHA 55%, QCHP 50%. Other regulators in the table below.

One failed attempt costs you the fee again, plus months of delay on your licence, your visa and your start date. This bank costs about a third of one exam fee.

Every regulator: format, pass marks and fees for all GCC licensing exams, each from the regulator's own documents.

The Radiographer exam at a glance

DHA (UAE) publishes a Radiographer exam of 150 MCQs in 3 hours with a 55% pass mark; DOH (UAE) publishes a Radiographer exam of 50-100 MCQs in 1-2 hours, scored pass or fail; SCFHS (Saudi Arabia) publishes a Radiographer exam of 200 MCQs in 240 minutes with a 530 on a 200-800 scale pass mark; QCHP (Qatar) publishes a Radiographer exam of 150 MCQs in 3 hours with a 50% pass mark. MOHAP, SHA, NHRA do not publish Radiographer-specific figures; their regulator-wide format and pass-mark rules are in the full table. OMSB, Kuwait MOH publish no exam for this title.

DHA · UAE
Radiographer (RAD5152)
150 MCQs in 3 hours · pass mark 55% · USD 240 (about AED 880) · checked September 2026
DOH · UAE
Radiography Technologist CBT
50-100 MCQs in 1-2 hours · pass mark Pass / fail only · AED 500 · checked October 2026
SCFHS · Saudi Arabia
Saudi Radiologic Technologist Licensure Examination (SRTLE)
200 MCQs in 240 minutes · pass mark 530 on a 200-800 scale · checked October 2026
QCHP · Qatar
Radiology Technologist
150 MCQs in 3 hours · pass mark 50% · checked September 2026

From each regulator's own exam documents; the DHA row is from the DHA CBT Guideline, Sep 2026. Every other regulator is in the full GCC table.

Try two questions from this bank

Original questions from the bank - pick an answer to see the rationale and reference.

Q1Radiation Physics & X-ray Production

As the linear energy transfer (LET) of a radiation increases, the relative biological effectiveness (RBE) generally:

Choose an answer to see the rationale.

Q2Anatomy, Physiology & Pathology (Clinical Principles)

Movement of the sole of the foot inward so that it faces the median plane is described as:

Choose an answer to see the rationale.

Not sure where you stand? Sit 25 of these questions free, timed at real exam pace, and see which domains you are weakest in.

Take the free mock exam →

Liked those? The full bank has 486 questions at this standard - every one with a rationale and a reference.

Get the full bank - AED 269

What's inside

  • ✓3 to 6 full-length papers (~160 Q each)
  • ✓No question repeated between papers
  • ✓Four options, one unambiguous best answer
  • ✓A full rationale on every question
  • ✓A real guideline or textbook reference
  • ✓Every sub-topic in the published blueprint
  • ✓Researched by Neelim's exam research team
  • ✓Prepared for your authority's exam, not a generic set

The Radiographer exam in every GCC country

Radiographer licensing exam in every GCC country
RegulatorExamFormatPass markFee per attempt
Radiographer (RAD5152)
150 MCQs in 3 hours55%USD 240 (about AED 880)
DOH
Abu Dhabi, Al Ain and Al Dhafra
Practise →
Radiography Technologist CBT
50-100 MCQs in 1-2 hoursPass / fail onlyAED 500
SCFHS
Kingdom of Saudi Arabia
Practise →
Saudi Radiologic Technologist Licensure Examination (SRTLE)
200 MCQs in 240 minutes530 on a 200-800 scaleNot published
QCHP
State of Qatar
Practise →
Radiology Technologist
150 MCQs in 3 hours50%Not published
MOHAP
Northern Emirates - Ajman, Umm Al Quwain, Ras Al Khaimah and Fujairah
Practise →
MOHAP licensing exam
Regulator-wide format
Computer-basedNot publishedNot published
SHA
Emirate of Sharjah
Practise →
SHA licensing exam
Regulator-wide format
Set at assessmentNot publishedNot published
NHRA
Kingdom of Bahrain
Practise →
NHRA licensing exam
Regulator-wide format
Prometric CBTNot publishedNot published
OMSB
Sultanate of Oman
Practise →
No exam published for this title
No OMSB exam published for this title; check with OMSB
Not publishedNot publishedNot published
Kuwait MOH
State of Kuwait
Practise →
No exam published for this title
Kuwait MOH publishes no exam for this title; check with the MOH
Not publishedNot publishedNot published

Highlighted rows publish figures for this exact Radiographer exam; the others show the regulator's general rules.

From each regulator's own exam pages; anything a regulator does not publish says so. Assessment mode also depends on your licence title, so confirm your route on your eligibility notice.

Try 15 free Radiographer questions with answersDifferent from the samples on this page - each with a full explanationStart →

What the Radiographer exam covers

The published blueprint for this exam breaks into 10 domains and 161 testable sub-topics. Our bank covers every one of them - here is the full map, so you can see exactly what you are expected to know.

Radiographic Positioning & Imaging Procedures~25% (SCFHS Procedure Management = 30% incl. clinical principles)23 topics
  • Upper extremity: finger, thumb, hand (PA/oblique/lateral), wrist incl. scaphoid (Stecher, ulnar deviation) and carpal tunnel
  • Forearm, elbow (AP, internal/external oblique, lateral, radial head laterals, acute flexion/Jones), humerus (AP, transthoracic lateral)
  • Shoulder girdle: AP internal/external/neutral rotation, Grashey/glenoid, scapular Y, Y-view, inferosuperior axial (Lawrence), clavicle (AP axial), AC joints (with/without weights), scapula
  • Lower extremity: toes, foot (AP axial, oblique, lateral, weight-bearing), calcaneus (plantodorsal/lateral), ankle (AP, mortise, oblique, stress views)
  • Tibia-fibula, knee (AP, oblique, lateral, weight-bearing), intercondylar fossa (tunnel/Holmblad/Camp-Coventry), patella (PA, lateral, tangential/sunrise/Settegast/Merchant)
  • Femur (AP/lateral), hip (AP, frog-leg lateral/Cleaves, cross-table/Danelius-Miller), pelvis (AP, inlet/outlet, AP axial)
  • +17 more in the bank
Anatomy, Physiology & Pathology (Clinical Principles)est. ~10% (part of SCFHS Procedure Management 30%)15 topics
  • Gross, sectional and relational anatomy of the skeletal system, thorax, abdomen, pelvis, skull and vertebral column
  • Cross-sectional anatomy for CT/MRI interpretation (axial, coronal, sagittal planes)
  • Anatomical terminology, body planes, positions, and directional terms
  • Physiology of major systems (respiratory, cardiovascular, GI, GU, musculoskeletal, nervous, endocrine)
  • Differentiating normal anatomical structures and recognizing normal variants on images
  • Skeletal fractures and classification: Colles, Smith, Monteggia, Galeazzi, Salter-Harris, greenstick, comminuted, compression, spiral, Boxer's, Bennett's, avulsion, Pott's, bimalleolar/trimalleolar, boxer's, hangman's, march
  • +9 more in the bank
Radiation Physics & X-ray Productionest. ~13% (part of SCFHS Operation of Equipment 25%)15 topics
  • Atomic structure, electromagnetic spectrum, and properties of x-rays
  • X-ray tube construction: cathode/filament, anode (rotating/stationary), focal spot, line-focus principle, target angle, anode heel effect
  • X-ray production: Bremsstrahlung and characteristic radiation; the x-ray emission spectrum
  • Generators and rectification (single/three-phase, high-frequency), kVp, mA, exposure time, mAs, and their control of beam quantity/quality
  • X-ray interactions with matter: photoelectric effect, Compton scatter, coherent scatter, pair production; relationship to contrast and dose
  • Beam filtration (inherent/added/total), half-value layer, beam quality/hardening
  • +9 more in the bank
Image Production, Processing & Quality (Operation of Equipment)~12% (part of SCFHS Operation of Equipment 25%)18 topics
  • Image receptors: computed radiography (CR/photostimulable phosphor) and digital radiography (DR/flat-panel, direct vs. indirect)
  • Exposure indicators (EI, S-number, EXI, deviation index) and detecting under/overexposure
  • Photographic (image) quality factors: density/brightness and contrast; controlling and influencing factors
  • Geometric factors: SID, OID, SOD; magnification, spatial resolution, and distortion (size/shape, foreshortening/elongation)
  • Recorded detail/sharpness, unsharpness (geometric, motion, absorption), and focal-spot blur/penumbra
  • Grids: grid ratio, frequency, types (linear/crossed/focused), grid cutoff, Bucky factor, air-gap technique, grid errors
  • +12 more in the bank
Radiation Protection & Safety~15% (part of SCFHS Health & Safety 20%)16 topics
  • ALARA principle and the cardinal rules of protection: time, distance, shielding
  • Dose-limitation system: justification, optimization, dose limits (occupational vs. public), effective dose limits
  • Occupational dose limits and the pregnant radiographer (declared pregnancy, fetal dose limits)
  • Personnel monitoring devices: film badge, TLD, OSL, pocket dosimeter; placement and reading
  • Patient dose-reduction techniques: collimation, gonadal/organ shielding, appropriate technique (high-kVp/low-mAs), minimizing repeats
  • Protective apparel and devices: lead aprons, thyroid shields, gloves, glasses; minimum lead equivalence and testing
  • +10 more in the bank
Patient Care & Management~15% (SCFHS Patient Management)16 topics
  • Patient identification (two identifiers), verifying the correct patient/procedure/site
  • Effective communication, informed consent, and ongoing consent during procedures
  • Respecting dignity, culture, religion, privacy, autonomy and confidentiality
  • Vital signs: normal ranges for temperature, pulse, respiration, blood pressure, SpO2, and their assessment
  • Patient transfer, transport, and safe moving/lifting with proper body mechanics
  • Immobilization devices and their appropriate use
  • +10 more in the bank
Contrast Media, Pharmacology & Drug Administrationest. ~7% (spans SCFHS Patient Management + Procedure Management)14 topics
  • Types of contrast media: barium sulfate (positive), water-soluble iodinated (ionic vs. non-ionic, high vs. low osmolar), gadolinium, negative/air contrast
  • Indications and contraindications for each contrast agent (e.g., barium contraindicated with suspected perforation)
  • Routes of administration: oral, rectal, intravenous, intra-arterial, intrathecal, intra-articular
  • Contrast reactions: mild, moderate, severe; recognition and management of anaphylactoid reactions
  • Emergency management of contrast reaction and crash-cart drugs (epinephrine, antihistamine, corticosteroid, oxygen)
  • Renal considerations: eGFR/creatinine screening, contrast-induced nephropathy, metformin and iodinated contrast
  • +8 more in the bank
Specialized Imaging Modalities (CT, MRI, US, Mammography, Nuclear Medicine, Fluoroscopy/Angiography)est. ~10% (embedded in SCFHS Operation of Equipment & Procedure Management)15 topics
  • CT fundamentals: generations/geometry, helical/multi-slice acquisition, pitch, collimation, reconstruction (FBP/iterative), kernels/filters
  • CT image parameters: Hounsfield units, window width/level, slice thickness, FOV, multiplanar reformatting, 3D rendering
  • CT dose metrics and reduction: CTDIvol, DLP, tube-current modulation, low-dose protocols
  • Common CT protocols: head, chest, abdomen/pelvis, CTA, contrast timing/bolus tracking
  • MRI physics: magnetism, T1/T2 relaxation, TR/TE, pulse sequences (SE, GRE, IR/FLAIR/STIR), image weighting and contrast
  • MRI hardware: magnet types/field strength, gradients, RF coils, encoding and image formation, k-space basics
  • +9 more in the bank
Infection Control & General/Occupational Safetyest. ~5% (part of SCFHS Health & Safety 20%)13 topics
  • Standard (routine) precautions and hand hygiene
  • Transmission-based precautions: contact, droplet, airborne isolation
  • Chain of infection and breaking transmission
  • Aseptic and sterile technique; establishing and maintaining a sterile field
  • Personal protective equipment: selection, donning/doffing sequence
  • Handling and disposal of sharps, contaminated and biohazardous materials
  • +7 more in the bank
Professional Practice, Ethics & Quality Assurance~10% (SCFHS Professional Practice)16 topics
  • Professional and ethical behavior, appearance, and unbiased care
  • Scope of practice: practicing within personal knowledge/skills and legal boundaries
  • Ethical principles: autonomy, beneficence, non-maleficence, justice, veracity, fidelity
  • Patient rights, confidentiality, and data protection (privacy of health information)
  • Informed consent (elements, capacity, and the radiographer's role)
  • Medico-legal concepts: negligence, malpractice, duty of care, standard of care, liability, documentation as evidence
  • +10 more in the bank

12 worked Radiographer practice questions

Original exam-style questions from the bank, spread across the blueprint domains. They are not real or recalled exam questions. Try each one, then open the answer for the rationale and reference. None of them appear in the free mock exam, so reading them will not spoil it.

  1. Question 1 · Radiographic Positioning & Imaging Procedures

    For a proximal femur DEXA scan, the leg is placed in approximately 15-25° of internal rotation using a positioning device. What is the purpose of this maneuver?

    1. ATo superimpose the greater and lesser trochanters
    2. BTo foreshorten the femoral neck and shorten scan time
    3. CTo position the femoral neck parallel to the table and present it at its true length for measurement
    4. DTo displace the femoral head out of the acetabulum
    Show answer and explanation

    Correct answer: C. To position the femoral neck parallel to the table and present it at its true length for measurement

    Internal rotation of about 15-25° brings the anteverted femoral neck parallel to the tabletop so it is projected at its true, elongated length, allowing the femoral-neck region of interest to be placed accurately and reproducibly. Correct rotation is confirmed when the lesser trochanter is small or barely visible; external rotation or neutral positioning foreshortens the neck and produces erroneous BMD values.

    Reference: International Society for Clinical Densitometry (ISCD) Official Positions (2019)

  2. Question 2 · Patient Care & Management

    A patient scheduled for a contrast-enhanced CT has a documented history of a previous severe (anaphylactoid) reaction to iodinated contrast. Which is the most appropriate management consideration?

    1. AGive the same contrast at a higher dose to overcome the reaction
    2. BSwitch to intrathecal administration of the same agent
    3. CProceed without any precautions because reactions never recur
    4. DConsider an alternative test or, if contrast is essential, use premedication and full resuscitation readiness after risk assessment
    Show answer and explanation

    Correct answer: D. Consider an alternative test or, if contrast is essential, use premedication and full resuscitation readiness after risk assessment

    A prior severe contrast reaction is a strong risk factor for recurrence, so the safest approach is to consider whether an alternative examination will answer the question, or, if iodinated contrast is truly necessary, to risk-assess, use premedication protocols and ensure full emergency preparedness. Repeating the same agent at a higher dose or with no precautions is dangerous, and intrathecal administration is unrelated and hazardous. Careful screening and mitigation are essential.

    Reference: ACR Manual on Contrast Media (2023); ESUR Guidelines on Contrast Agents

  3. Question 3 · Image Production, Processing & Quality (Operation of Equipment)

    A department performs 4000 exposures in a month and rejects 240 of them. The reject rate is 6%. If a benchmark target for general radiography is typically in the range of about 4-8%, the most appropriate interpretation is:

    1. AThe rate is far too low and indicates images are not being scrutinized
    2. BThe rate is dangerously high and the department should stop imaging
    3. CThe rate is acceptable but the categorized causes should still be reviewed for improvement opportunities
    4. DReject rate has no relationship to patient dose
    Show answer and explanation

    Correct answer: C. The rate is acceptable but the categorized causes should still be reviewed for improvement opportunities

    A 6% reject rate falls within commonly cited acceptable benchmarks (roughly 4-8%), so it does not indicate a crisis, but ongoing review of the categorized causes is still warranted to drive continuous improvement and further dose reduction. An unusually low rate can indicate under-scrutiny, but 6% is not low; and reject rates directly relate to dose because each repeat adds exposure.

    Reference: Papp, Quality Management in the Imaging Sciences, 6th ed. (2019)

  4. Question 4 · Specialized Imaging Modalities (CT, MRI, US, Mammography, Nuclear Medicine, Fluoroscopy/Angiography)

    When performing serial DEXA scans to monitor therapy, the least significant change (LSC) is used to determine whether an observed change in BMD is real. The LSC is derived primarily from:

    1. AThe scanner's spatial resolution
    2. BIn vivo precision (reproducibility) assessment of the facility/technologist
    3. CThe patient's T-score
    4. DThe manufacturer's reference database
    Show answer and explanation

    Correct answer: B. In vivo precision (reproducibility) assessment of the facility/technologist

    The least significant change is calculated from precision error established by repeated in vivo measurements at a given facility, ensuring that a change between scans exceeds normal measurement variability before being called significant. It is not derived from resolution, the T-score, or the reference database. ISCD requires each site to determine its own precision and LSC.

    Reference: ISCD Official Positions (2019)

  5. Question 5 · Contrast Media, Pharmacology & Drug Administration

    Which statement best characterises anaphylactoid (allergic-like) contrast reactions compared with physiologic (chemotoxic) reactions?

    1. AAnaphylactoid reactions are strictly dose-dependent and predictable from the injected volume
    2. BAnaphylactoid reactions are generally not dose-dependent and can occur after a small test dose
    3. CPhysiologic reactions always progress to anaphylaxis
    4. DBoth types are prevented completely by premedication
    Show answer and explanation

    Correct answer: B. Anaphylactoid reactions are generally not dose-dependent and can occur after a small test dose

    Anaphylactoid reactions resemble allergy but are not IgE-driven and are generally not dose-dependent, so a small volume can still trigger a severe response. Physiologic (chemotoxic) reactions such as warmth or nausea tend to relate to dose, osmolality, and volume and do not necessarily progress to anaphylaxis. Premedication reduces but does not eliminate reaction risk.

    Reference: ACR Manual on Contrast Media (2023)

  6. Question 6 · Radiographic Positioning & Imaging Procedures

    A horizontal-beam (cross-table) lateral projection of the knee is performed on a trauma patient. Demonstration of a fat-fluid level (lipohemarthrosis / FBI sign) in the suprapatellar region most reliably indicates which of the following?

    1. AA normal finding produced by knee flexion
    2. BChronic osteoarthritis of the knee
    3. CA purely inflammatory joint effusion
    4. DAn intra-articular fracture releasing marrow fat into the joint
    Show answer and explanation

    Correct answer: D. An intra-articular fracture releasing marrow fat into the joint

    A horizontal beam is required to demonstrate the fat-blood interface (FBI sign): marrow fat released by an intra-articular fracture floats on the denser blood, forming a visible fat-fluid level in the suprapatellar bursa. The buoyancy separation only appears on a horizontal-beam image and specifically signals cortical disruption, not a simple inflammatory effusion, a normal flexed knee, or degenerative change.

    Reference: Bontrager's Textbook of Radiographic Positioning and Related Anatomy, Lampignano & Kendrick, 10th ed. (2021)

  7. Question 7 · Patient Care & Management

    A radiographer must explain an intravenous urogram to a patient who speaks little of the local language. Which approach best supports valid informed consent?

    1. AAsk a passing porter to translate quickly to save time
    2. BAsk the patient's young child to translate the risks
    3. CHave the patient sign the form and explain nothing to avoid confusion
    4. DUse a professional or hospital-approved interpreter service to convey the information
    Show answer and explanation

    Correct answer: D. Use a professional or hospital-approved interpreter service to convey the information

    Valid consent requires the patient to genuinely understand the information, so a professional or approved interpreter should be used to overcome the language barrier. Ad-hoc translators such as porters or children may be inaccurate, breach confidentiality and cannot ensure medical terms are conveyed correctly. Obtaining a signature without explanation does not create informed consent.

    Reference: GMC Consent Guidance (2020); Society and College of Radiographers (SCoR) Consent to Imaging (2018)

  8. Question 8 · Image Production, Processing & Quality (Operation of Equipment)

    The line-focus principle allows a tube to have a small effective focal spot for sharpness while dissipating heat over a larger area. However, the effective focal spot size varies along the beam. Along the cathode-to-anode axis, the effective focal spot is:

    1. ALarger at the anode end of the field
    2. BUniform across the entire field
    3. CLarger at the cathode end of the field
    4. DSmallest at the central ray only
    Show answer and explanation

    Correct answer: C. Larger at the cathode end of the field

    Because of the projected geometry of the angled anode target, the effective focal spot appears larger toward the cathode side of the field and smaller toward the anode side. This means recorded detail is slightly better on the anode side. This is distinct from the anode heel effect, which concerns beam intensity rather than focal spot size.

    Reference: Bushong, Radiologic Science for Technologists, 12th ed. (2021)

  9. Question 9 · Specialized Imaging Modalities (CT, MRI, US, Mammography, Nuclear Medicine, Fluoroscopy/Angiography)

    For a pediatric chest CT, which single parameter change would most effectively reduce dose while sometimes even improving vascular/iodine contrast?

    1. ALowering kVp from 120 to 80-100
    2. BWidening the reconstruction kernel
    3. CIncreasing the rotation time
    4. DIncreasing kVp from 100 to 140
    Show answer and explanation

    Correct answer: A. Lowering kVp from 120 to 80-100

    Lowering kVp toward the k-edge of iodine (33 keV) increases iodine attenuation and contrast while substantially reducing dose, which is particularly beneficial in small pediatric patients. Increasing kVp raises dose, kernel choice does not change dose, and longer rotation time increases both dose and motion risk.

    Reference: Image Gently Alliance; Goo, Korean Journal of Radiology (2012)

  10. Question 10 · Contrast Media, Pharmacology & Drug Administration

    In a common elective oral corticosteroid premedication regimen, prednisone is given at approximately which time points before contrast injection?

    1. AOnly 5 minutes before
    2. B13, 7, and 1 hours before, with an antihistamine 1 hour before
    3. C24 and 48 hours after the scan
    4. DContinuously for one week prior
    Show answer and explanation

    Correct answer: B. 13, 7, and 1 hours before, with an antihistamine 1 hour before

    A widely cited elective regimen gives prednisone about 13, 7, and 1 hours before contrast, with an antihistamine (e.g., diphenhydramine) about 1 hour before. A single dose minutes before does not allow the corticosteroid to take effect, and dosing after the scan or for a week beforehand is not the standard prophylaxis.

    Reference: ACR Manual on Contrast Media (2023)

  11. Question 11 · Radiographic Positioning & Imaging Procedures

    Sialography of the parotid gland is requested. Which of the following is a contraindication to performing the examination at this time?

    1. AA palpable calculus within the salivary duct
    2. BAcute salivary gland infection (acute sialadenitis)
    3. CChronic dry mouth (xerostomia)
    4. DA history of a prior salivary duct stricture
    Show answer and explanation

    Correct answer: B. Acute salivary gland infection (acute sialadenitis)

    Sialography is contraindicated during acute salivary gland infection because cannulation and contrast injection can force organisms retrograde, worsen the inflammation, and cause severe pain. A ductal calculus, chronic xerostomia, and prior stricture are in fact common indications for the study, used to localize obstruction or map ductal anatomy once any acute infection has resolved.

    Reference: Merrill's Atlas of Radiographic Positioning and Procedures, 14th ed. (2023)

  12. Question 12 · Radiation Protection & Safety

    A referring physician requests a lumbar spine radiograph 'just to reassure' a patient who has no clinical signs and a normal recent examination. Under the ICRP system, the radiographer's primary protection concern with this request relates to which principle?

    1. AOptimisation, because the technique factors could be lowered
    2. BJustification, because the examination must produce sufficient benefit to outweigh the radiation detriment
    3. CDose limitation, because patient dose limits would be exceeded
    4. DApplication of diagnostic reference levels to the individual patient
    Show answer and explanation

    Correct answer: B. Justification, because the examination must produce sufficient benefit to outweigh the radiation detriment

    An examination without a valid clinical indication fails the principle of justification, which requires that the benefit to the patient outweigh the radiation detriment before any exposure. Optimisation and DRLs address how a justified exam is done, not whether it should occur, and dose limits do not apply to patient medical exposures at all.

    Reference: ICRP Publication 103 (2007); ICRP Publication 105 (2007)

Radiographer reference books and guidelines

Every question in this bank names the textbook or guideline its answer rests on. These are the sources our Radiographer questions cite most often - the reading list to revise from alongside the bank.

Textbooks

10
  1. 1

    ACR Manual on Contrast Media

    2023
  2. 2

    Bushong, Radiologic Science for Technologists

    12th edition2021
  3. 3

    Bontrager's Textbook of Radiographic Positioning and Related Anatomy, Lampignano & Kendrick

    10th edition2021
  4. 4

    Merrill's Atlas of Radiographic Positioning and Procedures

    14th edition2019
  5. 5

    Carlton & Adler, Principles of Radiographic Imaging

    6th edition2020
  6. 6

    ACR Manual on MR Safety

    2020
  7. 7

    ACR BI-RADS Atlas

    5th edition2013
  8. 8

    Greenspan's Orthopedic Imaging: A Practical Approach

    6th edition2015
  9. 9

    Papp, Quality Management in the Imaging Sciences

    6th edition2019
  10. 10

    Fundamentals of Diagnostic Radiology (Brant & Helms)

    5th edition2018

Guidelines and standards

10
  1. 1

    ESUR Guidelines on Contrast Agents, v10

    2018
  2. 2

    CDC Safe Injection Practices / Standard Precautions

    2011
  3. 3

    WHO Safe Management of Wastes from Health-care Activities

    2014
  4. 4

    Society and College of Radiographers Code of Professional Conduct

    2013
  5. 5

    CDC/HICPAC Guidelines for Environmental Infection Control in Health-Care Facilities

    2003
  6. 6

    OSHA Bloodborne Pathogens Standard (29 CFR 1910.1030)

  7. 7

    CDC Guideline for Prevention of Catheter-Associated Urinary Tract Infections

    2009
  8. 8

    British Thoracic Society Guideline for Oxygen Use in Adults

    2017
  9. 9

    GMC Consent Guidance

    2020
  10. 10

    ICRP Statement on Tissue Reactions

    2011

Where your regulator publishes a reading list, use the editions it names. Exam questions are not taken from any one book.

Last reviewed September 2026

About these questions: every question is original, researched by Neelim's exam research team, written to the published blueprint, with a rationale and a reference. No recalled or leaked exam content is used. How we write our questions.

Frequently asked questions

Are these real Radiographer exam questions?
No. Every item is original, researched by Neelim's exam research team against the exam blueprint published by the health authorities. Real, recalled or leaked exam content breaches the testing bodies' rules and can lead to a permanent exam ban - we do not sell it, and neither should anyone else.
How many questions are in the Radiographer bank?
Every bank starts at 3 full-length papers of roughly 160 questions each (the DHA exam itself is 150 questions), and you can add papers up to 6, including a bonus paper of our hardest questions. The papers do not overlap, so every question is new, and together they cover every sub-topic in the published blueprint.
What is the pass mark for the DHA Radiographer exam?
55%. DHA publishes the pass score for each exam, and 55% is the figure for Radiographer (RAD5152) in the DHA CBT Guideline, Sep 2026. The result is posted to your Sheryan account as Pass or Fail only - your score is not shared. Elsewhere in the GCC: DOH Pass / fail only, SCFHS 530 on a 200-800 scale, QCHP 50%.
How many questions are in the DHA Radiographer exam, and how long is it?
150 multiple-choice questions in 3 hours, and the time includes registration and the introduction. It is a computer-based test delivered by Prometric at test centres in the UAE and abroad.
How much does the DHA Radiographer exam cost?
USD 240 (about AED 880) per attempt, paid again for every re-sit. DHA also charges a flat AED 200 credentialing fee through Sheryan.
How many attempts do I get?
In the UAE, three in total across DHA, DOH, MOHAP and SHA, not three each, under clause 1.5.4 of the Unified PQR (April 2025). Clause 1.5.5 allows one further attempt with a different authority, except on the Consultant route. Elsewhere in the GCC: SCFHS up to 4 a year, QCHP 5 per scope, OMSB no set maximum, Kuwait MOH 3, 6 weeks apart.
Does this cover DHA, DOH, MOHAP, SCFHS and the other GCC regulators?
Yes, and it is not a generic set. Tell us which regulator you are sitting and we send the bank prepared for that authority's exam: its blueprint, its exam length and pass mark, and its local regulations. The core clinical knowledge is shared across the GCC; what changes by regulator is the test vendor (Prometric for DHA, SCFHS, QCHP, NHRA, Kuwait MOH; Pearson VUE for DOH, OMSB), the exam length, the pass mark, the local-regulation questions and, at some regulators such as DOH, an added oral or OSCE component. The table on this page shows each regulator's published format, pass mark and fee, and says where a figure is not published.
How do I receive it?
As PDF files. Card checkout is being set up, so for now you request it from this page and we send it to you directly, usually the same day.

Still unsure whether you even need this exam?

Your route depends on your profession, your licence title and the authority. We have guided over 1,000 professionals through GCC licensing - tell us your situation and we will confirm exactly what you need to sit.