Neelim للاستشارات الصحية
Neelim

Central Sterile Services Technician Prometric exam questions

Decontamination, packaging, sterilisation methods, monitoring and tracking.

Tell us which regulator you are sitting and we send the bank prepared for that authority's exam.

For DHA · DOH · MOHAP · SHA · SCFHS · NHRADHA STE5652Pass mark DHA 50% · SCFHS 60%From 3 papers · ~150 Qs each
AED 199one-time
About a quarter of one exam fee
Request this question bank

Tell us your authority and we send the bank for that exam, usually the same day.

Or sit 12 questions free first →

What is riding on this exam

~AED 880
DHA exam fee, per attempt
Paid again on every re-sit. Other regulators' fees are in the table below.
3
UAE attempts - in total
Shared across DHA, DOH, MOHAP and SHA, not three each. Saudi, Qatar, Oman and Kuwait rules are in the FAQ.
50-60%
Pass mark, by regulator
DHA 50%, SCFHS 60%. Other regulators in the table below.

One failed attempt costs you the fee again, plus months of delay on your licence, your visa and your start date. This bank costs about a quarter of one exam fee.

Every regulator: format, pass marks and fees for all GCC licensing exams, each from the regulator's own documents.

The Central Sterile Services Technician exam at a glance

DHA (UAE) publishes a Central Sterile Services Technician exam of 150 MCQs in 3 hours with a 50% pass mark; DOH (UAE) publishes a Central Sterile Services Technician exam of 50-100 MCQs in 1-2 hours, scored pass or fail; SCFHS (Saudi Arabia) publishes a Central Sterile Services Technician exam of 150 MCQs in 180 minutes with a 60% pass mark. MOHAP, SHA, NHRA do not publish Central Sterile Services Technician-specific figures; their regulator-wide format and pass-mark rules are in the full table. QCHP, OMSB, Kuwait MOH publish no exam for this title.

DHA · UAE
Central Sterile Services (CSS) Technician (STE5652)
150 MCQs in 3 hours · pass mark 50% · USD 240 (about AED 880) · checked September 2026
DOH · UAE
Central Sterile Services (CSS) Technician CBT
50-100 MCQs in 1-2 hours · pass mark Pass / fail only · AED 500 · checked October 2026
SCFHS · Saudi Arabia
Saudi Classification Examination - Sterilization Specialist
150 MCQs in 180 minutes · pass mark 60% · checked October 2026

From each regulator's own exam documents; the DHA row is from the DHA CBT Guideline, Sep 2026. Every other regulator is in the full GCC table.

Try two questions from this bank

Original questions from the bank - pick an answer to see the rationale and reference.

Q1Decontamination: Cleaning and Disinfection

How should the lumen of a suction tube be cleaned manually?

Choose an answer to see the rationale.

Q2Inspection, Assembly and Packaging

A stiff needle holder needs lubrication before steam sterilisation. Which product is appropriate?

Choose an answer to see the rationale.

Not sure where you stand? Sit 12 of these questions free, timed at real exam pace, and see which domains you are weakest in.

Take the free mock exam →

Liked those? The full bank has 450 questions at this standard - every one with a rationale and a reference.

Get the full bank - AED 199

What's inside

  • ✓3 to 6 full-length papers (~150 Q each)
  • ✓No question repeated between papers
  • ✓Four options, one unambiguous best answer
  • ✓A full rationale on every question
  • ✓A real guideline or textbook reference
  • ✓Every sub-topic in the published blueprint
  • ✓Researched by Neelim's exam research team
  • ✓Prepared for your authority's exam, not a generic set

The Central Sterile Services Technician exam in every GCC country

Central Sterile Services Technician licensing exam in every GCC country
RegulatorExamFormatPass markFee per attempt
Central Sterile Services (CSS) Technician (STE5652)
150 MCQs in 3 hours50%USD 240 (about AED 880)
DOH
Abu Dhabi, Al Ain and Al Dhafra
Practise →
Central Sterile Services (CSS) Technician CBT
50-100 MCQs in 1-2 hoursPass / fail onlyAED 500
SCFHS
Kingdom of Saudi Arabia
Practise →
Saudi Classification Examination - Sterilization Specialist
150 MCQs in 180 minutes60%Not published
MOHAP
Northern Emirates - Ajman, Umm Al Quwain, Ras Al Khaimah and Fujairah
Practise →
MOHAP licensing exam
Regulator-wide format
Computer-basedNot publishedNot published
SHA
Emirate of Sharjah
Practise →
SHA licensing exam
Regulator-wide format
Set at assessmentNot publishedNot published
QCHP
State of Qatar
Practise →
No exam published for this title
No DHP Qatar exam blueprint published for this title; check with DHP
Not publishedNot publishedNot published
NHRA
Kingdom of Bahrain
Practise →
NHRA licensing exam
Regulator-wide format
Prometric CBTNot publishedNot published
OMSB
Sultanate of Oman
Practise →
No exam published for this title
No OMSB exam published for this title; check with OMSB
Not publishedNot publishedNot published
Kuwait MOH
State of Kuwait
Practise →
No exam published for this title
Kuwait MOH publishes no exam for this title; check with the MOH
Not publishedNot publishedNot published

Highlighted rows publish figures for this exact Central Sterile Services Technician exam; the others show the regulator's general rules.

From each regulator's own exam pages; anything a regulator does not publish says so. Assessment mode also depends on your licence title, so confirm your route on your eligibility notice.

Try 15 free Central Sterile Services Technician questions with answersDifferent from the samples on this page - each with a full explanationStart →

What the Central Sterile Services Technician exam covers

The published blueprint for this exam breaks into 8 domains and 53 testable sub-topics. Our bank covers every one of them - here is the full map, so you can see exactly what you are expected to know.

Microbiology and Infection Prevention Principles~10%6 topics
  • Chain of infection and standard precautions
  • Spaulding classification: critical, semi-critical, non-critical
  • Hierarchy of microbial resistance to disinfection and sterilisation
  • Biofilm formation and the importance of prompt cleaning
  • Prions and instruments from suspected CJD cases
  • Point-of-use treatment and transport of contaminated items
Decontamination: Cleaning and Disinfection~18%8 topics
  • Manual cleaning: water temperature, brushes, lumen flushing
  • Detergents: enzymatic, neutral and alkaline; dilution and contact time
  • Ultrasonic cleaning and cavitation
  • Washer-disinfectors: cycle stages and A0 concept
  • Water quality for rinsing
  • High-level disinfection: glutaraldehyde, OPA, peracetic acid
  • Minimum effective concentration testing
  • Flexible endoscope reprocessing basics
Inspection, Assembly and Packaging~15%7 topics
  • Inspection with lighted magnification and function testing
  • Insulation testing of laparoscopic instruments
  • Instrument lubrication and care
  • Tray assembly, weight limits and instrument sets
  • Wrapping techniques and sterile barrier systems
  • Peel pouches: use and labelling
  • Internal and external chemical indicators
Steam Sterilisation~18%8 topics
  • Principles of moist heat sterilisation
  • Gravity displacement vs pre-vacuum cycles
  • Time and temperature parameters
  • Steriliser loading and unloading
  • Air removal testing: Bowie-Dick
  • Wet packs: causes and actions
  • Cooling and handling after the cycle
  • Immediate-use steam sterilisation
Low-Temperature Sterilisation~10%6 topics
  • Ethylene oxide: process, aeration and residues
  • Hydrogen peroxide gas plasma and vapour systems
  • Material and packaging compatibility
  • Liquid chemical sterilants
  • Biological indicators for low-temperature processes
  • Device manufacturer instructions for use
Monitoring, Quality Assurance and Traceability~14%7 topics
  • Physical monitoring: cycle printouts and parameters
  • Chemical indicator types and classes
  • Biological indicators and process challenge devices
  • Implant load release
  • Recall procedures after a failed indicator
  • Load records and instrument tracking
  • Validation, maintenance and audit
Sterile Storage and Distribution~7%5 topics
  • Event-related sterility and shelf life
  • Storage conditions: temperature, humidity, shelving clearances
  • Stock rotation and inventory management
  • Transport of sterile items
  • Handling of dropped or damaged packs
Workplace Safety and Professional Conduct~8%6 topics
  • Personal protective equipment in the decontamination area
  • Sharps safety and injury reporting
  • Chemical safety: safety data sheets, exposure limits
  • Ergonomics and manual handling
  • Workflow: dirty to clean, one-way traffic
  • Communication, documentation and professional responsibility

6 worked Central Sterile Services Technician practice questions

Original exam-style questions from the bank, spread across the blueprint domains. They are not real or recalled exam questions. Try each one, then open the answer for the rationale and reference. None of them appear in the free mock exam, so reading them will not spoil it.

  1. Question 1 · Decontamination: Cleaning and Disinfection

    A washer-disinfector thermal stage must achieve an A0 of 3000 for items contaminated with heat-resistant viruses. Which time and temperature gives this value?

    1. A90 degrees Celsius for 5 minutes
    2. B80 degrees Celsius for 1 minute
    3. C70 degrees Celsius for 10 minutes
    4. D60 degrees Celsius for 30 minutes
    Show answer and explanation

    Correct answer: A. 90 degrees Celsius for 5 minutes

    An A0 of 3000 corresponds to 90 degrees Celsius held for 5 minutes. An A0 of 600, used for lower-risk items, equals 80 degrees Celsius for 10 minutes.

    Reference: ISO 15883-1: Washer-disinfectors, General Requirements

  2. Question 2 · Inspection, Assembly and Packaging

    During inspection under lighted magnification, dried blood is found in the box joint of a clamp. What should be done?

    1. ADiscard the whole set
    2. BWipe it with alcohol and package it
    3. CPackage it, as sterilisation will kill microbes
    4. DReturn it for decontamination
    Show answer and explanation

    Correct answer: D. Return it for decontamination

    Any instrument with visible soil must be returned to decontamination and recleaned before packaging. Sterilisation cannot be relied on to penetrate soil.

    Reference: AAMI ST79: Comprehensive Guide to Steam Sterilization in Health Care Facilities

  3. Question 3 · Inspection, Assembly and Packaging

    Why is an internal chemical indicator placed inside every package?

    1. ATo record the steriliser number
    2. BTo prove the contents are sterile
    3. CTo show sterilant reached the contents
    4. DTo replace the biological indicator
    Show answer and explanation

    Correct answer: C. To show sterilant reached the contents

    An internal chemical indicator shows that the sterilant conditions reached the inside of the pack. It does not prove sterility, and it does not replace biological monitoring.

    Reference: AAMI ST79: Comprehensive Guide to Steam Sterilization in Health Care Facilities

  4. Question 4 · Low-Temperature Sterilisation

    A hydrogen peroxide low-temperature cycle repeatedly aborts with a load of flexible instruments. What is the most likely cause?

    1. AUsing polypropylene wrap
    2. BResidual moisture in the load
    3. CPlacing a chemical indicator inside
    4. DItems that are heat-sensitive
    Show answer and explanation

    Correct answer: B. Residual moisture in the load

    Residual water in lumens or on surfaces makes it hard to reach the required vacuum and commonly causes cycle cancellation, so items must be completely dry. Polypropylene wrap is compatible, and heat-sensitive items are the reason for using this method.

    Reference: AAMI ST58: Chemical Sterilization and High-level Disinfection in Health Care Facilities

  5. Question 5 · Microbiology and Infection Prevention Principles

    Neurosurgical instruments have been used on brain tissue of a patient later suspected of having Creutzfeldt-Jakob disease. What is the correct handling while the diagnosis is pending?

    1. AHigh-level disinfect them and reuse
    2. BProcess them in a routine steam cycle
    3. CQuarantine and do not reuse them
    4. DClean them and send them to the ward
    Show answer and explanation

    Correct answer: C. Quarantine and do not reuse them

    Prions resist standard processing, so instruments used on high-risk tissue in a suspected case are quarantined until the diagnosis is known and incinerated if confirmed. Routine processing does not reliably inactivate prions.

    Reference: WHO Infection Control Guidelines for Transmissible Spongiform Encephalopathies 1999

  6. Question 6 · Monitoring, Quality Assurance and Traceability

    A biological indicator from yesterday's steam load is positive. Which loads should be recalled?

    1. AOnly the load containing the positive BI
    2. BAll loads since the last negative BI
    3. COnly implant loads from today
    4. DNo loads, if the chemical indicators passed
    Show answer and explanation

    Correct answer: B. All loads since the last negative BI

    A positive BI means sterility cannot be assured, so all loads processed since the last negative BI from that steriliser are recalled and quarantined while the cause is investigated. Passing chemical indicators do not override a positive BI.

    Reference: AAMI ST79: Comprehensive Guide to Steam Sterilization in Health Care Facilities

Central Sterile Services Technician reference books and guidelines

Every question in this bank names the textbook or guideline its answer rests on. These are the sources our Central Sterile Services Technician questions cite most often - the reading list to revise from alongside the bank.

Textbooks

1
  1. 1

    AAMI ST79: Comprehensive Guide to Steam Sterilization in Health Care Facilities

Guidelines and standards

3
  1. 1

    CDC Guideline for Disinfection and Sterilization in Healthcare Facilities

    2008
  2. 2

    OSHA Standard 29 CFR 1910.1047: Ethylene Oxide

  3. 3

    WHO Infection Control Guidelines for Transmissible Spongiform Encephalopathies

    1999

Where your regulator publishes a reading list, use the editions it names. Exam questions are not taken from any one book.

Last reviewed September 2026

About these questions: every question is original, researched by Neelim's exam research team, written to the published blueprint, with a rationale and a reference. No recalled or leaked exam content is used. How we write our questions.

Frequently asked questions

Are these real Central Sterile Services Technician exam questions?
No. Every item is original, researched by Neelim's exam research team against the exam blueprint published by the health authorities. Real, recalled or leaked exam content breaches the testing bodies' rules and can lead to a permanent exam ban - we do not sell it, and neither should anyone else.
How many questions are in the Central Sterile Services Technician bank?
Every bank starts at 3 full-length papers of roughly 150 questions each, the same length as the real computer-based exam, and you can add papers up to 6, including a bonus paper of our hardest questions. The papers do not overlap, so every question is new, and together they cover every sub-topic in the published blueprint.
What is the pass mark for the DHA Central Sterile Services Technician exam?
50%. DHA publishes the pass score for each exam, and 50% is the figure for Central Sterile Services (CSS) Technician (STE5652) in the DHA CBT Guideline, Sep 2026. The result is posted to your Sheryan account as Pass or Fail only - your score is not shared. Elsewhere in the GCC: DOH Pass / fail only, SCFHS 60%.
How many questions are in the DHA Central Sterile Services Technician exam, and how long is it?
150 multiple-choice questions in 3 hours, and the time includes registration and the introduction. It is a computer-based test delivered by Prometric at test centres in the UAE and abroad.
How much does the DHA Central Sterile Services Technician exam cost?
USD 240 (about AED 880) per attempt, paid again for every re-sit. DHA also charges a flat AED 200 credentialing fee through Sheryan.
How many attempts do I get?
In the UAE, three in total across DHA, DOH, MOHAP and SHA, not three each, under clause 1.5.4 of the Unified PQR (April 2025). Clause 1.5.5 allows one further attempt with a different authority, except on the Consultant route. Elsewhere in the GCC: SCFHS up to 4 a year, QCHP 5 per scope, OMSB no set maximum, Kuwait MOH 3, 6 weeks apart.
Does this cover DHA, DOH, MOHAP, SCFHS and the other GCC regulators?
Yes, and it is not a generic set. Tell us which regulator you are sitting and we send the bank prepared for that authority's exam: its blueprint, its exam length and pass mark, and its local regulations. The core clinical knowledge is shared across the GCC; what changes by regulator is the test vendor (Prometric for DHA, SCFHS, QCHP, NHRA, Kuwait MOH; Pearson VUE for DOH, OMSB), the exam length, the pass mark, the local-regulation questions and, at some regulators such as DOH, an added oral or OSCE component. The table on this page shows each regulator's published format, pass mark and fee, and says where a figure is not published.
How do I receive it?
As PDF files. Card checkout is being set up, so for now you request it from this page and we send it to you directly, usually the same day.

Still unsure whether you even need this exam?

Your route depends on your profession, your licence title and the authority. We have guided over 1,000 professionals through GCC licensing - tell us your situation and we will confirm exactly what you need to sit.