Dental Lab Technician Prometric exam questions with answers
15 original practice questions written to the Dental Lab Technician exam blueprint, each with the answer and why the other options are wrong. Below them: the Dental Lab Technician exam's format, pass mark and fee at DHA, DOH, MOHAP, SHA, SCFHS, QCHP, NHRA, OMSB and Kuwait MOH, from their own published rules.
- 15
- Free questions
- 4
- Regulators publish this exam
- 55% / Pass / fail only
- Pass marks by regulator
- 12
- Questions in the free mock
Quick answer
The Dental Lab Technician exam is 150 MCQs in 3 hours at DHA (pass mark 55%), 50-100 MCQs in 1-2 hours at DOH (pass mark Pass / fail only), 150 MCQs in 180 minutes at SCFHS (pass mark 60%) and 150 MCQs in 3 hours at QCHP (pass mark 50%). Below are 15 original practice questions written to the official blueprint, each with the answer and why the other options are wrong, plus a free 12-question timed mock.
The full Dental Lab Technician bank: from 3 papers, ~150 questions each
AED 199 one-time
Every question with a rationale and a reference. PDF, lifetime access.
Tell us your authority and we send the bank for that exam, usually the same day.
The Dental Lab Technician exam in every GCC country
DHA, DOH, SCFHS, QCHP publish an exact Dental Lab Technician exam; the others apply one format to every title. Figures come from each regulator's own exam pages - anything not published says so.
| Regulator | Exam | Format | Pass mark | Fee per attempt |
|---|---|---|---|---|
Dental Lab Technician (DLT5521) | 150 MCQs in 3 hours | 55% | USD 240 (about AED 880) | |
Dental Lab Technician CBT | 50-100 MCQs in 1-2 hours | Pass / fail only | AED 500 | |
Saudi Classification Examination - Dental Laboratory Specialist | 150 MCQs in 180 minutes | 60% | Not published | |
Dental Lab Technician | 150 MCQs in 3 hours | 50% | Not published | |
MOHAP licensing exam Regulator-wide format | Computer-based | Not published | Not published | |
SHA licensing exam Regulator-wide format | Set at assessment | Not published | Not published | |
NHRA licensing exam Regulator-wide format | Prometric CBT | Not published | Not published | |
No exam published for this title No OMSB exam published for this title; check with OMSB | Not published | Not published | Not published | |
No exam published for this title Kuwait MOH publishes no exam for this title; check with the MOH | Not published | Not published | Not published |
Highlighted rows publish figures for this exact Dental Lab Technician exam; the others show the regulator's general rules.
Pass marks, attempts and fees change - confirm yours on the regulator's exam page before you book.
15 Dental Lab Technician exam questions with answers
Choose your answer first, then open the explanation. The set covers the main blueprint domains at a mix of easy, medium and hard.
- Question 1All-Ceramic Restorations and CAD/CAMmedium
A lithium disilicate CAD/CAM block is milled while it is bluish and relatively soft. What must be done before cementation?
- ASintering at about 1500 C for zirconia
- BHydrofluoric acid etch, no firing
- CAir abrasion with 250 micrometre alumina
- DCrystallisation firing in a furnace
Show answer and explanation
Answer: D. Crystallisation firing in a furnace
Lithium disilicate CAD blocks are milled in a partly crystallised metasilicate state and then fired to crystallise, which develops full strength and final shade. The high-temperature sintering cycle applies to zirconia.
Reference: Sakaguchi, Craig's Restorative Dental Materials, 14th ed.
- Question 2All-Ceramic Restorations and CAD/CAMhard
What mechanism gives yttria-stabilised zirconia its high fracture toughness?
- AGlass infiltration of surface porosity
- BLeucite crystals dispersed in a glass matrix
- CIon exchange strengthening of the surface
- DTetragonal-to-monoclinic phase transformation
Show answer and explanation
Answer: D. Tetragonal-to-monoclinic phase transformation
At a crack tip, metastable tetragonal grains transform to the larger monoclinic phase; the volume increase compresses the crack and resists its growth. Leucite reinforcement applies to some feldspathic glass-ceramics, not zirconia.
Reference: Anusavice, Phillips' Science of Dental Materials, 12th ed.
- Question 3Complete Denturesmedium
Which occlusal scheme is generally used in conventional complete dentures to improve stability during lateral and protrusive movements?
- ACanine-guided occlusion
- BBilateral balanced occlusion
- CGroup function only on working side
- DMutually protected occlusion
Show answer and explanation
Answer: B. Bilateral balanced occlusion
Bilateral balanced occlusion keeps contact on both sides during excursions, helping to stop the dentures tipping. Canine guidance suits natural dentitions but destabilises complete dentures.
Reference: Zarb, Prosthodontic Treatment for Edentulous Patients, 13th ed.
- Question 4Dental Anatomy, Occlusion and Articulatorsmedium
What is the main purpose of a facebow record sent with casts to the laboratory?
- ATo record the patient's vertical dimension of occlusion
- BTo record the shade of the teeth
- CTo record lateral condylar guidance only
- DTo mount the upper cast relative to the hinge axis
Show answer and explanation
Answer: D. To mount the upper cast relative to the hinge axis
A facebow transfers the position of the maxillary arch in relation to the terminal hinge axis, so the cast is mounted correctly on the articulator. Vertical dimension is recorded with occlusal records, not the facebow.
Reference: Shillingburg, Fundamentals of Fixed Prosthodontics, 4th ed.
- Question 5Orthodontic and Other Applianceseasy
A dentist requests a custom sports mouthguard for a rugby player. Which material is most commonly vacuum-formed or pressure-formed for this?
- AEthylene vinyl acetate (EVA)
- BHeat-cured PMMA acrylic sheet
- CCast cobalt-chromium alloy
- DType IV dental stone
Show answer and explanation
Answer: A. Ethylene vinyl acetate (EVA)
Custom mouthguards are thermoformed from ethylene vinyl acetate sheets, which absorb impact and are comfortable. PMMA is rigid and used for denture bases and hard splints.
Reference: ADA Councils: Using mouthguards to reduce orofacial injuries, JADA 2006
- Question 6Dental Materials Sciencemedium
Which investment is required for casting a high-fusing alloy for a metal-ceramic crown?
- AGypsum-bonded investment
- BType II model plaster
- CPhosphate-bonded investment
- DSilicone putty
Show answer and explanation
Answer: C. Phosphate-bonded investment
Phosphate-bonded investments withstand the high casting temperatures of metal-ceramic and base metal alloys. Gypsum-bonded investments break down above about 700 C and are used only for lower-fusing gold alloys.
Reference: Anusavice, Phillips' Science of Dental Materials, 12th ed.
- Question 7Removable Partial Dentureshard
A cast cobalt-chromium circumferential clasp is being designed. How deep should its retentive tip engage the undercut?
- A0.75 mm
- B1.0 mm
- C0.25 mm
- D1.5 mm
Show answer and explanation
Answer: C. 0.25 mm
Cobalt-chromium is stiff, so its clasp tips should engage only about 0.25 mm of undercut. Deeper undercuts, around 0.5-0.75 mm, are used for more flexible gold or wrought wire clasps.
Reference: McCracken's Removable Partial Prosthodontics, 13th ed.
- Question 8Removable Partial Dentureseasy
Which instrument is used to determine the path of insertion and locate undercuts on a partial denture cast?
- AFacebow
- BArticulator
- CDental surveyor
- DBoley gauge
Show answer and explanation
Answer: C. Dental surveyor
A dental surveyor, with its analysing rod and undercut gauges, finds the path of insertion, height of contour and undercut depth. A facebow records the maxillary arch position relative to the hinge axis.
Reference: McCracken's Removable Partial Prosthodontics, 13th ed.
Halfway - how are you scoring?
Test yourself under real exam conditions
The free 12-question mock is timed and scored against the pass mark, domain by domain, so you see exactly where you are losing marks. The full Dental Lab Technician bank starts at 3 full-length papers of about 150 questions each for AED 199, one-time, and you can add papers up to 6.
Tell us your authority and we send the bank for that exam, usually the same day.
- Question 9Dental Materials Sciencemedium
An addition silicone impression has unset, tacky areas where it touched the putty handled by a gloved technician. What is the most likely cause?
- AExcess catalyst in the mix
- BOver-long working time
- CMoisture from the tray adhesive
- DSulfur compounds from latex gloves
Show answer and explanation
Answer: D. Sulfur compounds from latex gloves
Sulfur compounds from latex gloves poison the platinum catalyst of addition silicones and inhibit setting. Using vinyl or nitrile gloves, or washing hands first, avoids this.
Reference: Craig's Restorative Dental Materials, 14th ed.
- Question 10Fixed Prosthodontics and Metal-Ceramicsmedium
Where should die spacer be applied on a prepared die?
- AOver the finish line margin only, nowhere else
- BOver the preparation, stopping short of the margin
- COn the entire die surface, including the margin
- DOnly on the occlusal surface
Show answer and explanation
Answer: B. Over the preparation, stopping short of the margin
Die spacer creates room for luting cement but must stop about 0.5-1 mm short of the finish line so the casting fits closely at the margin. Covering the margin would leave an open margin.
Reference: Shillingburg, Fundamentals of Fixed Prosthodontics, 4th ed.
- Question 11Laboratory Safety, Infection Control and Ethicsmedium
An alginate impression arrives in the laboratory in a sealed bag. What is the correct first handling step?
- ARinse, then disinfect for the stated time
- BPour it at once, without any disinfection
- CSoak it in tap water overnight
- DAutoclave it at 134 C first
Show answer and explanation
Answer: A. Rinse, then disinfect for the stated time
Impressions are treated as contaminated: they are rinsed to remove saliva and blood, then disinfected with a compatible agent for the stated contact time before pouring. Overnight soaking distorts alginate, and autoclaving destroys it.
Reference: CDC Guidelines for Infection Control in Dental Health-Care Settings 2003
- Question 12Laboratory Safety, Infection Control and Ethicsmedium
A laboratory grinds a base metal alloy that contains beryllium. What is the main health risk?
- ASkin burns from contact with the alloy
- BChronic lung disease from inhaled dust
- CHearing loss from grinding noise
- DEye damage from ultraviolet light
Show answer and explanation
Answer: B. Chronic lung disease from inhaled dust
Inhaling beryllium dust or fumes can cause chronic beryllium disease, a granulomatous lung disease, so local exhaust ventilation is needed during grinding and melting. The alloy itself does not cause skin burns on contact.
Reference: Anusavice, Phillips' Science of Dental Materials, 12th ed.
- Question 13Laboratory Safety, Infection Control and Ethicsmedium
A dentist's prescription asks for a metal-ceramic crown, but the technician thinks zirconia would look better. What should the technician do?
- AMake zirconia and inform the dentist later
- BMake both and let the patient choose
- CFollow the prescription without comment
- DContact the dentist before changing the design
Show answer and explanation
Answer: D. Contact the dentist before changing the design
The written prescription defines the device; any change in material or design needs the prescribing dentist's agreement first. Following it silently loses the chance to raise a valid concern.
Reference: General Dental Council: Standards for the Dental Team
- Question 14Orthodontic and Other Appliancesmedium
Which stainless steel wire diameter is typically used to make an Adams clasp on a permanent first molar?
- A0.3 mm
- B0.7 mm
- C1.2 mm
- D2.0 mm
Show answer and explanation
Answer: B. 0.7 mm
An Adams clasp on permanent molars is usually made in 0.7 mm hard stainless steel wire; 0.6 mm is used for deciduous molars. Wire of 1.2 mm is too stiff to engage the undercut.
Reference: Isaacson, Removable Orthodontic Appliances
- Question 15Removable Partial Denturesmedium
A maxillary arch has bilateral free-end saddles and a separate missing lateral incisor. Under Applegate's rules, how is it classified?
- AClass IV, modification 1
- BClass I, modification 1
- CClass II, modification 2
- DClass III, modification 2
Show answer and explanation
Answer: B. Class I, modification 1
The most posterior edentulous areas determine the class (Class I), and additional spaces are counted as modifications. Class IV can never have modification spaces, so the Class IV option is wrong.
Reference: McCracken's Removable Partial Prosthodontics, 13th ed.
What the Dental Lab Technician exam covers
The blueprint groups questions into these domains. Weight your revision the same way - the heavier domains carry more of your score.
Dental Materials Science
~16%Gypsum products · Impression materials · Investments
Fixed Prosthodontics and Metal-Ceramics
~16%Die preparation and die spacer · Wax pattern and spruing · Lost-wax casting and casting defects
All-Ceramic Restorations and CAD/CAM
~12%Lithium disilicate · Zirconia · Surface treatment of ceramics for bonding
Removable Partial Dentures
~14%Kennedy classification and Applegate's rules · Surveying and path of insertion · Clasp design and undercut depth
Complete Dentures
~12%Record blocks and jaw relationship records · Posterior palatal seal · Tooth selection and arrangement
Orthodontic and Other Appliances
~8%Removable orthodontic appliances · Retainers · Occlusal splints and sports mouthguards
Dental Anatomy, Occlusion and Articulators
~10%Tooth notation systems · Crown morphology of permanent teeth · Occlusal curves and planes
Laboratory Safety, Infection Control and Ethics
~12%Disinfection of impressions and appliances · Dust, silica and local exhaust ventilation · Chemical hazards
How to answer these questions
Diagnosis questions hinge on one or two discriminating findings - pick them out of the stem before reading the options.
Know the order of treatment planning cold: emergency relief, disease control, then restorative and prosthetic phases.
Infection control, radiation safety and ethics are short, high-yield marks - do not skip them in revision.
Aim to score comfortably above your regulator's pass mark - 10 to 15 points of margin - on timed, full-length practice before you book.
The full Dental Lab Technician bank: from 3 papers, ~150 questions each
AED 199 one-time
Every question with a rationale and a reference. PDF, lifetime access.
Tell us your authority and we send the bank for that exam, usually the same day.
Dental Lab Technician exam questions: FAQs
How many questions are in the Dental Lab Technician Prometric exam?
What is the pass mark for the Dental Lab Technician exam?
Are these real exam questions?
Is the Dental Lab Technician exam the same in every GCC country?
How should I use these questions?
Last reviewed September 2026. Questions are original and written to the published exam blueprint; they are not taken from any real paper.
More free exam questions
Pass the Dental Lab Technician exam first time
Not sure which regulator's exam you need, or whether you are exempt? Tell us your profession and target country - we confirm your route and the exact exam before you book.