DHA Central Sterile Services Technician exam questions
Decontamination, packaging, sterilisation methods, monitoring and tracking.
Card checkout is being set up. We send it directly, usually the same day.
What is riding on this exam
One failed attempt costs you the fee again, plus months of delay on your licence, your visa and your start date. This bank costs about a fifth of one exam fee.
Pass marks at a glance: DHA exam codes and pass marks for all written exams in one sourced table.
DHA Central Sterile Services Technician exam at a glance
- Exam code
- STE5652
- Questions
- 150 MCQs
- Duration
- 3 hours
- Pass mark
- 50%
- Fee per attempt
- USD 240 (about AED 880)
- Result
- Pass or fail, no score
From the DHA CBT Guideline, Sep 2026. Delivered by Prometric; three attempts in total across the UAE authorities. Full DHA exam guide.
Try two questions from this bank
Original questions from the bank - pick an answer to see the rationale and reference.
How should the lumen of a suction tube be cleaned manually?
Choose an answer to see the rationale.
A stiff needle holder needs lubrication before steam sterilisation. Which product is appropriate?
Choose an answer to see the rationale.
Not sure where you stand? Sit 12 of these questions free, timed at real exam pace, and see which domains you are weakest in.
Take the free mock exam →Liked those? The full bank has 450 questions at this standard - every one with a rationale and a reference.
Get the full bank - AED 179What's inside
- ✓3 full-length papers (~150 Q each)
- ✓450 questions, no overlap between papers
- ✓Four options, one unambiguous best answer
- ✓A full rationale on every question
- ✓A real guideline or textbook reference
- ✓Every sub-topic in the published blueprint
The Central Sterile Services Technician exam in every GCC country
| Regulator | Exam | Format | Pass mark | Fee per attempt | Practise |
|---|---|---|---|---|---|
| DHA Dubai | Central Sterile Services (CSS) Technician (STE5652) | 150 MCQs in 3 hours | 50% | USD 240 (about AED 880) | DHA questions → |
| DOH Abu Dhabi, Al Ain and Al Dhafra | DOH licensing exam Regulator-wide format | Written + oral/OSCE | Pass / fail only | Not published | DOH questions → |
| MOHAP Northern Emirates - Ajman, Umm Al Quwain, Ras Al Khaimah and Fujairah | MOHAP licensing exam Regulator-wide format | Computer-based | Not published | Not published | MOHAP questions → |
| SHA Emirate of Sharjah | SHA licensing exam Regulator-wide format | Set at assessment | Not published | Not published | SHA questions → |
| SCFHS Kingdom of Saudi Arabia | SCFHS licensing exam Regulator-wide format | 200 MCQs, 240 min | 500-560 of 800 | Not published | SCFHS questions → |
| QCHP State of Qatar | QCHP licensing exam Regulator-wide format | 150 MCQs, 3 hrs | 50-65% | Not published | QCHP questions → |
| NHRA Kingdom of Bahrain | NHRA licensing exam Regulator-wide format | Prometric CBT | Not published | Not published | NHRA questions → |
| OMSB Sultanate of Oman | OMSB licensing exam Regulator-wide format | Computer-based OC exam | Not published | Not published | OMSB questions → |
| Kuwait MOH State of Kuwait | Kuwait MOH licensing exam Regulator-wide format | 150 MCQs, 170 min | 60-70% | Not published | Kuwait MOH questions → |
exact exam published for Central Sterile Services Technician
From each regulator's own exam pages; anything a regulator does not publish says so. Assessment mode also depends on your licence title, so confirm your route on your eligibility notice.
Try 15 free Central Sterile Services Technician questions with answersDifferent from the samples on this page - each with a full explanationStart →What the Central Sterile Services Technician exam covers
The published blueprint for this exam breaks into 8 domains and 53 testable sub-topics. Our bank covers every one of them - here is the full map, so you can see exactly what you are expected to know.
Microbiology and Infection Prevention Principles~10%6 topics
- Chain of infection and standard precautions
- Spaulding classification: critical, semi-critical, non-critical
- Hierarchy of microbial resistance to disinfection and sterilisation
- Biofilm formation and the importance of prompt cleaning
- Prions and instruments from suspected CJD cases
- Point-of-use treatment and transport of contaminated items
Decontamination: Cleaning and Disinfection~18%8 topics
- Manual cleaning: water temperature, brushes, lumen flushing
- Detergents: enzymatic, neutral and alkaline; dilution and contact time
- Ultrasonic cleaning and cavitation
- Washer-disinfectors: cycle stages and A0 concept
- Water quality for rinsing
- High-level disinfection: glutaraldehyde, OPA, peracetic acid
- Minimum effective concentration testing
- Flexible endoscope reprocessing basics
Inspection, Assembly and Packaging~15%7 topics
- Inspection with lighted magnification and function testing
- Insulation testing of laparoscopic instruments
- Instrument lubrication and care
- Tray assembly, weight limits and instrument sets
- Wrapping techniques and sterile barrier systems
- Peel pouches: use and labelling
- Internal and external chemical indicators
Steam Sterilisation~18%8 topics
- Principles of moist heat sterilisation
- Gravity displacement vs pre-vacuum cycles
- Time and temperature parameters
- Steriliser loading and unloading
- Air removal testing: Bowie-Dick
- Wet packs: causes and actions
- Cooling and handling after the cycle
- Immediate-use steam sterilisation
Low-Temperature Sterilisation~10%6 topics
- Ethylene oxide: process, aeration and residues
- Hydrogen peroxide gas plasma and vapour systems
- Material and packaging compatibility
- Liquid chemical sterilants
- Biological indicators for low-temperature processes
- Device manufacturer instructions for use
Monitoring, Quality Assurance and Traceability~14%7 topics
- Physical monitoring: cycle printouts and parameters
- Chemical indicator types and classes
- Biological indicators and process challenge devices
- Implant load release
- Recall procedures after a failed indicator
- Load records and instrument tracking
- Validation, maintenance and audit
Sterile Storage and Distribution~7%5 topics
- Event-related sterility and shelf life
- Storage conditions: temperature, humidity, shelving clearances
- Stock rotation and inventory management
- Transport of sterile items
- Handling of dropped or damaged packs
Workplace Safety and Professional Conduct~8%6 topics
- Personal protective equipment in the decontamination area
- Sharps safety and injury reporting
- Chemical safety: safety data sheets, exposure limits
- Ergonomics and manual handling
- Workflow: dirty to clean, one-way traffic
- Communication, documentation and professional responsibility
6 worked Central Sterile Services Technician practice questions
Original exam-style questions from the bank, spread across the blueprint domains. They are not real or recalled exam questions. Try each one, then open the answer for the rationale and reference. None of them appear in the free mock exam, so reading them will not spoil it.
Question 1 · Decontamination: Cleaning and Disinfection
A washer-disinfector thermal stage must achieve an A0 of 3000 for items contaminated with heat-resistant viruses. Which time and temperature gives this value?
- A90 degrees Celsius for 5 minutes
- B80 degrees Celsius for 1 minute
- C70 degrees Celsius for 10 minutes
- D60 degrees Celsius for 30 minutes
Show answer and explanation
Correct answer: A. 90 degrees Celsius for 5 minutes
An A0 of 3000 corresponds to 90 degrees Celsius held for 5 minutes. An A0 of 600, used for lower-risk items, equals 80 degrees Celsius for 10 minutes.
Reference: ISO 15883-1: Washer-disinfectors, General Requirements
Question 2 · Inspection, Assembly and Packaging
During inspection under lighted magnification, dried blood is found in the box joint of a clamp. What should be done?
- ADiscard the whole set
- BWipe it with alcohol and package it
- CPackage it, as sterilisation will kill microbes
- DReturn it for decontamination
Show answer and explanation
Correct answer: D. Return it for decontamination
Any instrument with visible soil must be returned to decontamination and recleaned before packaging. Sterilisation cannot be relied on to penetrate soil.
Reference: AAMI ST79: Comprehensive Guide to Steam Sterilization in Health Care Facilities
Question 3 · Inspection, Assembly and Packaging
Why is an internal chemical indicator placed inside every package?
- ATo record the steriliser number
- BTo prove the contents are sterile
- CTo show sterilant reached the contents
- DTo replace the biological indicator
Show answer and explanation
Correct answer: C. To show sterilant reached the contents
An internal chemical indicator shows that the sterilant conditions reached the inside of the pack. It does not prove sterility, and it does not replace biological monitoring.
Reference: AAMI ST79: Comprehensive Guide to Steam Sterilization in Health Care Facilities
Question 4 · Low-Temperature Sterilisation
A hydrogen peroxide low-temperature cycle repeatedly aborts with a load of flexible instruments. What is the most likely cause?
- AUsing polypropylene wrap
- BResidual moisture in the load
- CPlacing a chemical indicator inside
- DItems that are heat-sensitive
Show answer and explanation
Correct answer: B. Residual moisture in the load
Residual water in lumens or on surfaces makes it hard to reach the required vacuum and commonly causes cycle cancellation, so items must be completely dry. Polypropylene wrap is compatible, and heat-sensitive items are the reason for using this method.
Reference: AAMI ST58: Chemical Sterilization and High-level Disinfection in Health Care Facilities
Question 5 · Microbiology and Infection Prevention Principles
Neurosurgical instruments have been used on brain tissue of a patient later suspected of having Creutzfeldt-Jakob disease. What is the correct handling while the diagnosis is pending?
- AHigh-level disinfect them and reuse
- BProcess them in a routine steam cycle
- CQuarantine and do not reuse them
- DClean them and send them to the ward
Show answer and explanation
Correct answer: C. Quarantine and do not reuse them
Prions resist standard processing, so instruments used on high-risk tissue in a suspected case are quarantined until the diagnosis is known and incinerated if confirmed. Routine processing does not reliably inactivate prions.
Reference: WHO Infection Control Guidelines for Transmissible Spongiform Encephalopathies 1999
Question 6 · Monitoring, Quality Assurance and Traceability
A biological indicator from yesterday's steam load is positive. Which loads should be recalled?
- AOnly the load containing the positive BI
- BAll loads since the last negative BI
- COnly implant loads from today
- DNo loads, if the chemical indicators passed
Show answer and explanation
Correct answer: B. All loads since the last negative BI
A positive BI means sterility cannot be assured, so all loads processed since the last negative BI from that steriliser are recalled and quarantined while the cause is investigated. Passing chemical indicators do not override a positive BI.
Reference: AAMI ST79: Comprehensive Guide to Steam Sterilization in Health Care Facilities
Last reviewed September 2026
About these questions: every question is original, written to the published blueprint, with a rationale and a reference. No recalled or leaked exam content is used. How we write our questions.
Before you book your exam
Frequently asked questions
Are these real Central Sterile Services Technician exam questions?
How many questions are in the Central Sterile Services Technician bank?
What is the pass mark for the DHA Central Sterile Services Technician exam?
How many questions are in the DHA Central Sterile Services Technician exam, and how long is it?
How much does the DHA Central Sterile Services Technician exam cost?
How many attempts do I get?
Does this cover DHA, DOH, MOHAP and SCFHS?
How do I receive it?
Still unsure whether you even need this exam?
Your route depends on your profession, your licence title and the authority. We have guided over 1,000 professionals through GCC licensing - tell us your situation and we will confirm exactly what you need to sit.