Free DOH EEG / Neurodiagnostic Technologist mock test
25 original exam-style questions from our EEG / Neurodiagnostic Technologist bank, timed at the exam’s own pace, with an instant score. They span 7 of the 7 blueprint domains, so you will see exactly where you are weakest - free, no sign-up.
Sit 25 original exam-style questions at real exam pace
These are 25 original questions taken from our EEG / Neurodiagnostic Technologist bank, spread across 7 of the 7 domains of the published blueprint. You get 72 seconds per question, which is exactly the pace of the real exam (30 minutes for 25). At the end you will see which domains you are weakest in, and the full worked reasoning for every question.
- 25
- questions
- 30:00
- time limit
- Varies
- pass mark by authority
A short diagnostic cannot predict whether you will pass - only the real exam does that. It will show you, honestly, where you currently stand.
Quick answer
The EEG / Neurodiagnostic Technologist exam at a glance
The EEG / Neurodiagnostic Technologist licensing exam is a computer-based, multiple-choice test, and each GCC regulator sets its own. DOH publishes exact figures, listed below. This free mock gives you 25 original exam-style questions at 72 seconds each, then shows your weakest domains.
Published exam figures
- DOH
Electro-Neurodiagnostics Technologist CBT + Oral
UAE50-100 MCQs1-2 hoursplus a 40-60 minute oralPass / fail only
pass mark
- Attempts in the UAE
- 3 in total across DHA, DOH, MOHAP and SHA
- This free mock
- 25 questions · 30 minutes · 7 of 7 domains
- Full bank
- 450+ questions · 3 to 6 papers · AED 269
- Regulators
- DOH
How this free EEG / Neurodiagnostic Technologist mock works
- 25
- original questions
- 30 min
- time limit
- 72s
- per question
- 7 of 7
- blueprint domains
- You get 72 seconds per question, the pace of a 150-question paper in 3 hours. The timer runs in your browser and ends the sitting when it reaches zero.
- No regulator publishes a percentage pass mark for this exam, so your score is shown on its own and each domain is compared with your overall result.
- At the end you see your score, your pace per question, every domain ranked weakest first, and the worked answer and source for all 25 questions.
- You can mark each answer “sure” or “not sure”. Wrong answers you were sure about are shown first, because they are the ones you would not stop to check in the real exam.
- Your last result is saved in your own browser only, so you can come back and compare. Nothing is sent to us.
What the real EEG / Neurodiagnostic Technologist licensing exam looks like
The EEG / Neurodiagnostic Technologist exam is a computer-based multiple-choice paper, published by one regulator: DOH (pass mark Pass / fail only). Every regulator's format, pass mark and fee is in the table below; confirm yours before booking.
Pass marks at a glance: exam codes and pass marks by regulator for every written exam in one sourced table.
Before you can book the exam at all you need Dataflow primary source verification of your degree, licence and experience, which typically runs several weeks. Candidates often underestimate this and end up sitting the exam sooner after study than they planned. Check where you stand with our free eligibility checker or confirm whether your title even requires an exam using the Prometric exam checker.
You get three attempts in total across all UAE authorities, not three each, under the Unified Professional Qualification Requirements. At roughly AED 880 per attempt, plus the licensing delay each failure adds to your visa and start date, the cost of going in underprepared is not really the exam fee.
| Regulator | Exam | Format | Pass mark | Fee per attempt |
|---|---|---|---|---|
Electro-Neurodiagnostics Technologist CBT + Oral | 50-100 MCQs in 1-2 hours, plus a 40-60 minute oral | Pass / fail only | AED 550 | |
No exam published for this title Not in the DHA CBT list; DHA's guideline assesses licensed titles that are not listed by oral | Not published | Not published | Not published | |
No exam published for this title MOHAP publishes no exam for this title that we could find; check with MOHAP | Not published | Not published | Not published | |
No exam published for this title SHA publishes no exam for this title that we could find; check with SHA | Not published | Not published | Not published | |
No exam published for this title Not in the SCFHS classification exam list; check the title with SCFHS | Not published | Not published | Not published | |
No exam published for this title No DHP Qatar exam blueprint published for this title; check with DHP | Not published | Not published | Not published | |
No exam published for this title NHRA publishes no exam for this title that we could find; check with NHRA | Not published | Not published | Not published | |
No exam published for this title No OMSB exam published for this title; check with OMSB | Not published | Not published | Not published | |
No exam published for this title Kuwait MOH publishes no exam for this title; check with the MOH | Not published | Not published | Not published |
Highlighted rows publish figures for this exact EEG / Neurodiagnostic Technologist exam; the others show the regulator's general rules.
What is on the EEG / Neurodiagnostic Technologist exam: the full blueprint
The published blueprint splits into 7 domains and 59 testable sub-topics. For each one you can see its weight, how many questions this mock asks on it, and about how many the full bank holds.
- Neuroanatomy and Neurophysiology~14%
6 sub-topics · 6 in this mock · about 63 in the full bank
Neelim estimate, no official weights published
- EEG Instrumentation and Recording Technique~19%
8 sub-topics · 3 in this mock · about 86 in the full bank
Neelim estimate, no official weights published
- Normal EEG and Artifacts~17%
7 sub-topics · 4 in this mock · about 77 in the full bank
Neelim estimate, no official weights published
- Abnormal EEG, Seizures and Epilepsy~19%
8 sub-topics · 5 in this mock · about 86 in the full bank
Neelim estimate, no official weights published
- Evoked Potentials, Nerve Conduction and EMG~14%
6 sub-topics · 4 in this mock · about 63 in the full bank
Neelim estimate, no official weights published
- Patient Care, Infection Control and Safety~10%
4 sub-topics · 2 in this mock · about 45 in the full bank
Neelim estimate, no official weights published
- Professional Practice and Ethics~7%
3 sub-topics · 1 in this mock · about 32 in the full bank
Neelim estimate, no official weights published
Bank counts are estimates from the published weights the bank is written to, rounded.
This mock samples 7 of 7 domains. The full bank covers all 7 across 450+ questions.
See the full bank - AED 269How to use your mock score
No regulator publishes a percentage pass mark for this exam, so the total matters less than the domain map. Treat any domain below your own overall score as a priority, and confirm the pass rule with your regulator before you book.
Getting an honest score
- 1Sit it cold, once. Do not look anything up. A diagnostic you help yourself through tells you nothing. The number you get is only useful if it is honest.
- 2Read every rationale, especially the ones you got right. Getting a question right by elimination is not the same as knowing it. The worked reasoning is free, whether or not you buy anything.
- 3Work on your weakest domain first. The breakdown orders your domains worst first for exactly this reason. Studying what you are already good at feels productive and moves nothing.
- 4Re-sit under full exam conditions later. The real paper is much longer than 25 questions and stamina matters. The full bank's 3 to 6 papers are written for exactly this.
A worked EEG / Neurodiagnostic Technologist exam question
Every question in the mock and in the paid bank is written to this standard: a clinical stem, four plausible options and the reasoning for the answer, with its source.
Abnormal EEG, Seizures and Epilepsy
A child stares and stops responding for about 10 seconds many times a day, and the EEG shows generalized 3 Hz spike-and-wave. Which provocation is most likely to trigger events during recording?
- APhotic stimulation at 1 Hz
- BSleep deprivation only
- CEye closure
- DHyperventilationCorrect
Why: Typical absence seizures with 3 Hz spike-and-wave are strongly activated by hyperventilation. The other procedures are less reliable.
Source: Ebersole JS, Pedley TA, Current Practice of Clinical Electroencephalography, 4th ed. (2014)
EEG / Neurodiagnostic Technologist sample questions with answers
10 more original exam-style EEG / Neurodiagnostic Technologist questions, worked in full. They are not real or recalled exam questions, and none of them is in the mock above or on the bank page, so sit the mock first if you have not.
Question 1 · Abnormal EEG, Seizures and Epilepsy
An infant with spasms has a chaotic, high-voltage, disorganized EEG with multifocal spikes. What is this pattern called?
- ABurst suppression
- BHypsarrhythmia
- CTriphasic waves
- DPeriodic lateralized epileptiform discharges
Show answer and explanation
Correct answer: B. Hypsarrhythmia
Hypsarrhythmia is the chaotic high-amplitude background of infantile spasms (West syndrome). Burst suppression has alternating silence, triphasic waves are surface-positive blunt waves in metabolic disease and PLEDs are lateralized periodic.
Reference: Ebersole JS, Pedley TA, Current Practice of Clinical Electroencephalography, 4th ed. (2014)
Question 2 · Abnormal EEG, Seizures and Epilepsy
In a suspected case of electrocerebral inactivity, which technical change is recommended by the ACNS standard?
- AUse a notch filter alone and avoid all other filters
- BRecord only a 10-second sample at 7 microvolts per mm
- CUse sensitivity of at least 2 microvolts per mm, with interelectrode distances of at least 10 cm and a 30-minute recording
- DUse only the standard 10-20 bipolar chain at default settings
Show answer and explanation
Correct answer: C. Use sensitivity of at least 2 microvolts per mm, with interelectrode distances of at least 10 cm and a 30-minute recording
The cerebral death protocol requires high sensitivity (2 uV/mm), long interelectrode distances and at least 30 minutes of recording, with integrity checks. Default routine settings or a short sample are inadequate.
Reference: American Clinical Neurophysiology Society, Guideline 3: Minimum Technical Standards for EEG Recording in Suspected Cerebral Death (2016)
Question 3 · EEG Instrumentation and Recording Technique
What does a longer time constant on the low-frequency filter do to slow activity such as delta waves?
- AIt removes more slow activity from the record, because the low-frequency cutoff rises as the time constant lengthens
- BIt has no effect on delta activity, which is determined only by the setting of the high-frequency filter
- CIt converts slow waves into spike-like transients by differentiating the signal at the input stage
- DIt passes more slow activity, because the low-frequency filter cutoff falls
Show answer and explanation
Correct answer: D. It passes more slow activity, because the low-frequency filter cutoff falls
The low-frequency cutoff is roughly 1/(2 pi x TC), so a longer time constant gives a lower cutoff and passes slower activity. A shorter one attenuates delta and slow drift. Delta is governed by the low filter, and filters do not create spikes.
Reference: Ebersole JS, Pedley TA, Current Practice of Clinical Electroencephalography, 4th ed. (2014)
Question 4 · EEG Instrumentation and Recording Technique
Which standard recording settings are typical for a routine adult EEG display?
- APaper speed 5 mm per second, sensitivity 100 microvolts per mm
- BPaper speed 30 mm per second, sensitivity 7 microvolts per mm
- CPaper speed 60 mm per second, sensitivity 70 microvolts per mm
- DPaper speed 15 mm per second, sensitivity 1 microvolt per mm
Show answer and explanation
Correct answer: B. Paper speed 30 mm per second, sensitivity 7 microvolts per mm
A 30 mm/s speed and 7 uV/mm sensitivity are the usual adult routine display settings. The other combinations would compress the trace, hide cerebral activity or exaggerate it.
Reference: American Clinical Neurophysiology Society, Guideline 1: Minimum Technical Requirements for Performing Clinical Electroencephalography (2016)
Question 5 · EEG Instrumentation and Recording Technique
On a referential montage using an ear reference, every channel shows the same sharp waveform at the same moment, with no field. Which source is most likely?
- AActivity at the reference electrode, so change the reference or montage
- BPoorly prepared skin at the occipital electrodes, so clean the sites again
- CA true generalised seizure discharge with a wide field
- DNormal alpha activity spreading to the other channels from the back
Show answer and explanation
Correct answer: A. Activity at the reference electrode, so change the reference or montage
A waveform that appears in every channel referenced to the same electrode points to contamination of the reference, such as ECG or temporal activity at the ear electrode. Switching to a different reference or a bipolar montage will confirm this. A true generalised discharge would vary between channels, and poor skin prep affects individual channels.
Reference: American Clinical Neurophysiology Society, Guideline 6: A Proposal for Standard Montages to Be Used in Clinical EEG (2016)
Question 6 · Normal EEG and Artifacts
At what age does the posterior dominant rhythm in a waking child normally reach about 8 Hz?
- AAbout ten years of age
- BAt birth
- CAbout three years of age
- DAbout one year of age
Show answer and explanation
Correct answer: C. About three years of age
The posterior dominant rhythm develops with age, starting near 4 Hz in infancy and reaching about 8 Hz by around three years. A slower rhythm than expected at that age should be reported for interpretation.
Reference: Tatum WO, Handbook of EEG Interpretation, 3rd edition (2021)
Question 7 · Abnormal EEG, Seizures and Epilepsy
Why is sleep deprivation sometimes requested before a diagnostic EEG?
- AIt guarantees that a seizure will occur during recording
- BIt increases the chance of recording epileptiform discharges
- CIt removes muscle artifact from the recording
- DIt lowers electrode impedance at the scalp sites after skin preparation
Show answer and explanation
Correct answer: B. It increases the chance of recording epileptiform discharges
Sleep deprivation and recording of sleep raise the yield of interictal epileptiform discharges in many patients with epilepsy. It does not guarantee a seizure, reduce artifact or change electrode impedance.
Reference: American Clinical Neurophysiology Society, Guideline 1: Minimum Technical Requirements for Performing Clinical Electroencephalography (2016)
Question 8 · Evoked Potentials, Nerve Conduction and EMG
On needle EMG performed by the physician, a muscle shows small, short-duration, polyphasic motor unit potentials with early recruitment. Which condition do these findings suggest?
- AChronic reinnervation after nerve injury
- BA primary muscle disorder, such as a myopathy
- CUpper motor neuron weakness from a stroke
- DA neuromuscular junction disorder such as botulism
Show answer and explanation
Correct answer: B. A primary muscle disorder, such as a myopathy
Small, short, polyphasic units with early recruitment reflect loss of muscle fibres within each motor unit, typical of myopathy. Chronic reinnervation produces large, long units with reduced recruitment, and stroke gives normal units with reduced activation.
Reference: Preston DC, Shapiro BE, Electromyography and Neuromuscular Disorders, 4th edition (2020)
Question 9 · Patient Care, Infection Control and Safety
A patient scheduled for a physician-performed needle EMG takes warfarin and has an INR of 3.5. What should the technologist do?
- AInform the supervising physician before starting, as the INR is raised
- BProceed as planned, because EMG needles are too fine to cause bleeding
- CTell the patient to stop the warfarin and return after a week
- DSample deep muscles first, to reduce the number of insertions
Show answer and explanation
Correct answer: A. Inform the supervising physician before starting, as the INR is raised
Needle EMG carries a small bleeding risk, so anticoagulation with a high INR must be reported to the supervising physician, who decides whether and how to proceed. Needles are not too fine to bleed, and stopping warfarin is a prescriber decision that the technologist must not make. Sampling deep muscles first does not lower the risk.
Reference: Preston DC, Shapiro BE, Electromyography and Neuromuscular Disorders, 4th edition (2020)
Question 10 · Professional Practice and Ethics
A technologist wants to email an EEG file to a colleague's personal account for a second opinion. What is the correct response?
- APost it to a public file-sharing site and send the colleague the link
- BSend it, as the patient's name has been removed from the subject line
- CSend it if the colleague promises to delete it after reading the report
- DDecline, and use only the facility's approved secure sharing system
Show answer and explanation
Correct answer: D. Decline, and use only the facility's approved secure sharing system
UAE Federal Law No. 2 of 2019 requires confidentiality and secure handling of health information, so sharing must use approved systems. A removed subject line, a promise to delete or a public link do not protect the data.
Reference: UAE Federal Law No. 2 of 2019 on the Use of Information and Communications Technology in Health Fields
Free mock vs the full EEG / Neurodiagnostic Technologist bank
The mock tells you where you stand. The bank is how you close the gap.
| What you get | Free mock | Full bank |
|---|---|---|
| Questions | 25 | 450+ |
| Papers | 1 short timed set | 3 to 6 full-length papers, about 150 each |
| Blueprint coverage | 7 of 7 domains | All 7 domains, 59 sub-topics |
| Worked rationale | Every question | Every question |
| Reference | Every question | Every question |
| Timing | 30 minutes in your browser | Exam-length papers to sit against the clock |
| Format | Online, free | PDF sent to you, yours to keep |
| Price | Free | AED 269, paid once |
Full EEG / Neurodiagnostic Technologist bank
Close your gaps before exam day
- 450+ original questions in 3 to 6 full-length papers
- A worked rationale and a reference on every question
- Prepared for your regulator's blueprint and pass mark
One-time price
AED 269
About a third of one exam fee (about AED 880 per attempt)
Unlock the full bank →No subscription · yours to keep
Frequently asked questions
Is this EEG / Neurodiagnostic Technologist mock test really free?
Are these real EEG / Neurodiagnostic Technologist exam questions?
What is the pass mark for the EEG / Neurodiagnostic Technologist exam?
How long is the EEG / Neurodiagnostic Technologist exam and how many questions?
What topics does the EEG / Neurodiagnostic Technologist exam cover?
How is the full EEG / Neurodiagnostic Technologist bank different from this mock?
Does passing this mock mean I will pass the real exam?
Which regulators is this EEG / Neurodiagnostic Technologist mock for?
How many attempts do I get at the real exam?
Other free mock exams in allied
Keep going
From a 25-question mock to the full EEG / Neurodiagnostic Technologist bank
450+ original questions in 3 to 6 full-length papers, each with a worked rationale and a reference, written to the same blueprint as the free mock on this page. One price: AED 269.