Neelim Healthcare Consulting
Neelim

Free Hematology Laboratory mock test

12 original exam-style questions from our Hematology Laboratory bank, timed at the exam’s own pace, scored against the 55% DHA pass mark. They span 7 of the 8 blueprint domains, so you will see exactly where you are weakest - free, no sign-up.

DHA MTH4612Pass mark DHA 55% · SCFHS 60%

Free diagnosticNo sign-up · no email · results instantly

Sit 12 original exam-style questions at real exam pace

These are 12 original questions taken from our Hematology Laboratory bank, spread across 7 of the 8 domains of the published blueprint. You get 72 seconds per question, which is exactly the pace of the real MTH4612 exam (14 minutes for 12). At the end you will see which domains you are weakest in, and the full worked reasoning for every question.

12
questions
14:24
time limit
55%
DHA pass mark

A short diagnostic cannot predict whether you will pass - only the real exam does that. It will show you, honestly, where you currently stand.

Quick answer

The Hematology Laboratory exam at a glance

The Hematology Laboratory licensing exam is a computer-based, multiple-choice test, and each GCC regulator sets its own. DHA and SCFHS publish exact figures, listed below. This free mock gives you 12 original exam-style questions at 72 seconds each, scored against the 55% DHA pass mark, then shows your weakest domains.

Published exam figures

  • DHA

    Hematology Technologist (MTH4612)

    UAE150 MCQs3 hours

    55%

    pass mark

  • SCFHS

    Saudi Classification Examination - Laboratory - Hematology Specialist

    Saudi Arabia150 MCQs180 minutes

    60%

    pass mark

Attempts in the UAE
3 in total across DHA, DOH, MOHAP and SHA
This free mock
12 questions · 14 minutes · 7 of 8 domains
Full bank
450+ questions · 3 to 6 papers · AED 269
Regulators
DHA, SCFHS, DOH, MOHAP, SHA, QCHP, NHRA, OMSB and Kuwait MOH

How this free Hematology Laboratory mock works

12
original questions
14 min
time limit
72s
per question
7 of 8
blueprint domains
  • You get 72 seconds per question, the pace of a 150-question paper in 3 hours. The timer runs in your browser and ends the sitting when it reaches zero.
  • Your score is set against the 55% DHA pass mark, the published figure for this exam. No other number is invented: there is no percentile and no pass probability.
  • At the end you see your score, your pace per question, every domain ranked weakest first, and the worked answer and source for all 12 questions.
  • You can mark each answer “sure” or “not sure”. Wrong answers you were sure about are shown first, because they are the ones you would not stop to check in the real exam.
  • Your last result is saved in your own browser only, so you can come back and compare. Nothing is sent to us.

What the real Hematology Laboratory licensing exam looks like

The Hematology Laboratory exam is a computer-based multiple-choice paper, published by 2 regulators: DHA MTH4612 (pass mark 55%), SCFHS (pass mark 60%). Every regulator's format, pass mark and fee is in the table below; confirm yours before booking.

Pass marks at a glance: exam codes and pass marks by regulator for every written exam in one sourced table.

Before you can book the exam at all you need Dataflow primary source verification of your degree, licence and experience, which typically runs several weeks. Candidates often underestimate this and end up sitting the exam sooner after study than they planned. Check where you stand with our free eligibility checker or confirm whether your title even requires an exam using the Prometric exam checker.

You get three attempts in total across all UAE authorities, not three each, under the Unified Professional Qualification Requirements. At roughly AED 880 per attempt, plus the licensing delay each failure adds to your visa and start date, the cost of going in underprepared is not really the exam fee.

Hematology Laboratory licensing exam in every GCC country
RegulatorExamFormatPass markFee per attempt
Hematology Technologist (MTH4612)
150 MCQs in 3 hours55%USD 240 (about AED 880)
SCFHS
Kingdom of Saudi Arabia
Practise →
Saudi Classification Examination - Laboratory - Hematology Specialist
150 MCQs in 180 minutes60%Not published
DOH
Abu Dhabi, Al Ain and Al Dhafra
Practise →
DOH licensing exam
Regulator-wide format
Written + oral/OSCEPass / fail onlyNot published
MOHAP
Northern Emirates - Ajman, Umm Al Quwain, Ras Al Khaimah and Fujairah
Practise →
MOHAP licensing exam
Regulator-wide format
Computer-basedNot publishedNot published
SHA
Emirate of Sharjah
Practise →
SHA licensing exam
Regulator-wide format
Set at assessmentNot publishedNot published
QCHP
State of Qatar
Practise →
No exam published for this title
No DHP Qatar exam blueprint published for this title; check with DHP
Not publishedNot publishedNot published
NHRA
Kingdom of Bahrain
Practise →
NHRA licensing exam
Regulator-wide format
Prometric CBTNot publishedNot published
OMSB
Sultanate of Oman
Practise →
No exam published for this title
No OMSB exam published for this title; check with OMSB
Not publishedNot publishedNot published
Kuwait MOH
State of Kuwait
Practise →
No exam published for this title
Kuwait MOH publishes no exam for this title; check with the MOH
Not publishedNot publishedNot published

Highlighted rows publish figures for this exact Hematology Laboratory exam; the others show the regulator's general rules.

What is on the Hematology Laboratory exam: the full blueprint

The published blueprint splits into 8 domains and 50 testable sub-topics. For each one you can see its weight, how many questions this mock asks on it, and about how many the full bank holds.

  • Haematopoiesis and Blood Cell Morphology~12%

    6 sub-topics · 1 in this mock · about 54 in the full bank

  • Red Cell Disorders and Anaemia~18%

    7 sub-topics · 4 in this mock · about 81 in the full bank

  • Haemoglobinopathies and Thalassaemias~10%

    6 sub-topics · 1 in this mock · about 45 in the full bank

  • White Cell Disorders and Haematological Malignancy~15%

    7 sub-topics · 2 in this mock · about 68 in the full bank

  • Haemostasis and Coagulation~18%

    8 sub-topics · 1 in this mock · about 81 in the full bank

  • Automation, Flow Cytometry and Quality Control~12%

    6 sub-topics · 1 in this mock · about 54 in the full bank

  • Specimen Handling, Laboratory Safety and Ethics~8%

    5 sub-topics · not in this mock · about 36 in the full bank

  • Special Haematology Tests~7%

    5 sub-topics · 2 in this mock · about 32 in the full bank

Bank counts are estimates from the published weights the bank is written to, rounded.

This mock samples 7 of 8 domains. The full bank covers all 8 across 450+ questions, including the one domain this mock does not reach.

See the full bank - AED 269

How to use your mock score

These bands are set against the 55% DHA pass mark and match the verdict on your result screen. On 12 questions, a score near the pass mark has a 95% margin of error of about ±28 points, so treat the band as a direction, not a forecast.

Below 50%

Below the line

On this sample you would likely fall short of the 55% pass mark today. Do not book yet. Start with your two weakest domains from the result, then sit full-length papers until you clear the line with room to spare.

50% to 64%

Close to the line

A few questions decide it. On a 150-question paper, every 1% is one or two questions, so drill your weakest domains and build a margin on timed papers before you book.

65% and above

On track

Clear of the pass mark on this sample. 12 questions is a small sample, so confirm it over full-length timed papers before you book: stamina and pacing fail candidates who know the material.

Getting an honest score

  1. 1Sit it cold, once. Do not look anything up. A diagnostic you help yourself through tells you nothing. The number you get is only useful if it is honest.
  2. 2Read every rationale, especially the ones you got right. Getting a question right by elimination is not the same as knowing it. The worked reasoning is free, whether or not you buy anything.
  3. 3Work on your weakest domain first. The breakdown orders your domains worst first for exactly this reason. Studying what you are already good at feels productive and moves nothing.
  4. 4Re-sit under full exam conditions later. The real paper is much longer than 12 questions and stamina matters. The full bank's 3 to 6 papers are written for exactly this.

A worked Hematology Laboratory exam question

Every question in the mock and in the paid bank is written to this standard: a clinical stem, four plausible options and the reasoning for the answer, with its source.

Automation, Flow Cytometry and Quality Control

In the impedance method used by many haematology analysers, how are cells counted and sized?

  1. ALight absorbance of a lysed blood sample
  2. BResistance pulses as cells pass an apertureCorrect
  3. CFluorescence of nucleic acid dyes alone
  4. DVisual comparison with a standard film

Why: In the Coulter impedance principle, each cell passing through an aperture causes a pulse in electrical resistance proportional to its volume, allowing counting and sizing. Light absorbance of lysed blood is used to measure haemoglobin, not to count cells.

Source: Dacie and Lewis Practical Haematology, 12th ed.

Hematology Laboratory sample questions with answers

4 more original exam-style Hematology Laboratory questions, worked in full. They are not real or recalled exam questions, and none of them is in the mock above or on the bank page, so sit the mock first if you have not.

  1. Question 1 · Automation, Flow Cytometry and Quality Control

    Two consecutive results of the same control level both exceed +2 SD from the mean. Which Westgard rule is violated and what type of error does it suggest?

    1. A1-2s, a warning only
    2. BR-4s, random error
    3. C2-2s, systematic error
    4. D10x, imprecision
    Show answer and explanation

    Correct answer: C. 2-2s, systematic error

    The 2-2s rule is violated when two consecutive control results exceed the same 2 SD limit, indicating systematic error, and the run should be rejected and investigated. R-4s detects random error when results within a run differ by more than 4 SD.

    Reference: Westgard JO et al. Clin Chem 1981 (multirule QC)

  2. Question 2 · Haemostasis and Coagulation

    An older woman with new extensive bruising has an isolated prolonged APTT. An immediate 1:1 mix corrects, but after 2 hours at 37 C the mixed APTT is prolonged again. What is the most likely cause?

    1. AFactor XII deficiency
    2. BAcquired factor VIII inhibitor
    3. CLupus anticoagulant
    4. DVitamin K deficiency
    Show answer and explanation

    Correct answer: B. Acquired factor VIII inhibitor

    Acquired factor VIII autoantibodies are typically time and temperature dependent, so correction is seen immediately but lost after incubation. A lupus anticoagulant usually fails to correct immediately, and factor XII deficiency does not cause bleeding.

    Reference: Tiede A et al. International Recommendations on Acquired Hemophilia A, Haematologica 2020

  3. Question 3 · Haemostasis and Coagulation

    A patient's PT is 18 seconds, the mean normal PT is 12 seconds and the thromboplastin ISI is 2.0. What is the INR?

    1. A1.5
    2. B3.0
    3. C3.5
    4. D2.25
    Show answer and explanation

    Correct answer: D. 2.25

    INR = (patient PT / mean normal PT) to the power of ISI = (18 / 12)^2.0 = 1.5^2 = 2.25. Multiplying the ratio by the ISI instead of raising it to that power gives the incorrect value of 3.0.

    Reference: WHO Guidelines for Thromboplastins and Plasma Used to Control Oral Anticoagulant Therapy 2013

  4. Question 4 · Haemoglobinopathies and Thalassaemias

    A 24-year-old has Hb 118 g/L, MCV 63 fL, normal ferritin and an HbA2 of 5.2% by HPLC. What is the most likely diagnosis?

    1. ABeta-thalassaemia trait
    2. BIron deficiency anaemia
    3. CAlpha-thalassaemia trait
    4. DSickle cell trait
    Show answer and explanation

    Correct answer: A. Beta-thalassaemia trait

    Marked microcytosis with normal iron stores and an HbA2 above 3.5% is diagnostic of beta-thalassaemia trait. Alpha-thalassaemia trait has a normal or low HbA2 and requires DNA analysis for confirmation.

    Reference: BSH Guideline: Significant Haemoglobinopathies, Laboratory Diagnosis 2023

Last reviewed September 2026. About these questions: every item is original, written to the published blueprint, with a rationale and a reference, and no recalled or leaked exam content is used. How we write our questions.

Free mock vs the full Hematology Laboratory bank

The mock tells you where you stand. The bank is how you close the gap.

Free Hematology Laboratory mock compared with the full bank
What you getFree mockFull bank
Questions12450+
Papers1 short timed set3 to 6 full-length papers, about 150 each
Blueprint coverage7 of 8 domainsAll 8 domains, 50 sub-topics
Worked rationaleEvery questionEvery question
ReferenceEvery questionEvery question
Timing14 minutes in your browserExam-length papers to sit against the clock
FormatOnline, freePDF sent to you, yours to keep
PriceFreeAED 269, paid once

Full Hematology Laboratory bank

Close your gaps before exam day

  • 450+ original questions in 3 to 6 full-length papers
  • A worked rationale and a reference on every question
  • Prepared for your regulator's blueprint and pass mark

One-time price

AED 269

About a third of one exam fee (about AED 880 per attempt)

Unlock the full bank →

No subscription · yours to keep

Frequently asked questions

Is this Hematology Laboratory mock test really free?
Yes. All 12 questions, your score, the domain breakdown and the full worked answers are free, with no sign-up, no email and no payment. The paid Hematology Laboratory bank is a separate, much larger set of 450+ questions across 3 to 6 papers at AED 269.
Are these real Hematology Laboratory exam questions?
No. They are original questions written to the published Hematology Laboratory blueprint and drawn from our full bank, not leaked or recalled items. Recalled questions breach exam security rules and are often out of date. These follow the exam's format and domain weighting.
What is the pass mark for the Hematology Laboratory exam?
By regulator: DHA MTH4612 (pass mark 55%), SCFHS (pass mark 60%), each from the regulator's own exam documents. Regulators not listed publish no figure for this exam, so confirm yours before booking. Most report only pass or fail and never release your score, which is why a diagnostic like this is useful.
How long is the Hematology Laboratory exam and how many questions?
DHA: 150 MCQs in 3 hours; SCFHS: 150 MCQs in 180 minutes, from each regulator's own exam documents (DHA's time includes registration and the introduction, per the DHA CBT Guideline, Sep 2026). Regulators not listed publish no length for this exam, so confirm theirs in the current candidate bulletin.
What topics does the Hematology Laboratory exam cover?
The published blueprint has 8 domains and 50 testable sub-topics. The heaviest are Red Cell Disorders and Anaemia (~18%), Haemostasis and Coagulation (~18%) and White Cell Disorders and Haematological Malignancy (~15%). The full domain list with weights is on this page.
How is the full Hematology Laboratory bank different from this mock?
This mock is 12 questions across 7 of the 8 blueprint domains, enough to rank your domains. The full bank is 450+ questions in 3 to 6 full-length papers of about 150 questions, covering every domain, with about 81 questions on Red Cell Disorders and Anaemia alone. Every question has a worked rationale and a reference. It costs AED 269, paid once.
What score should I aim for on this Hematology Laboratory mock?
Aim for at least 65%, which is 10 points over the 55% DHA pass mark. Below 50% you would likely fall short today; between 50% and 64% a few questions decide it. On 12 questions a score near the pass mark has a margin of error of about ±28 points, so read it as a direction.
Does passing this mock mean I will pass the real exam?
No, and we will not claim otherwise. 12 questions cannot predict a full-length paper: the margin of error is about ±28 points. What it does reliably show is which blueprint domains you are weakest in, so you know where to start.
Which regulators is this Hematology Laboratory mock for?
It is written to the shared Hematology Laboratory blueprint, so it fits DHA, SCFHS, DOH, MOHAP, SHA, QCHP, NHRA, OMSB and Kuwait MOH. DHA and SCFHS publish an exam for this exact title. What changes by regulator is the length, the pass mark and the local regulation questions.
How many attempts do I get at the real exam?
In the UAE, three in total across DHA, DOH, MOHAP and SHA under the Unified Professional Qualification Requirements, not three per authority. Each attempt costs roughly AED 880, which is why it pays to find your weak domains first.

Other free mock exams in allied

From a 12-question mock to the full Hematology Laboratory bank

450+ original questions in 3 to 6 full-length papers, each with a worked rationale and a reference, written to the same blueprint as the free mock on this page. One price: AED 269.